industrial chiller units
industrial chiller units
industrial chiller units
industrial chiller units
industrial chiller units
industrial chiller units
industrial chiller units
industrial chiller units

1 / 6

industrial chiller units

Get Latest Price
Send Inquiry
Model No. : WD-5AC
Brand Name : WINDAY

Product description

industrial chiller units   Winday Industrial is a professional industrial water chiller manufacture in Shanghai, China. Successfully passed ISO9001 certification, CE certification, and has been successfully registered trademark  "WINDAY".
Water chiller STRONG POINTS:
1 Chiller compressor brand is Copeland USA.Scroll compressor. Or Danfoss/Daikin/Sanyo optional is customer appointed
2 Evaporator is plate type or copper shell and tube type,copper tube wall thickness is 0.7mm
3 Condenser is  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger
4 Pump and water systems are stainless steel SUS304
5 High quality level electronic parts, Schneider/Siemens/LS
6 Designed chiller running life 10 years(running 8hr per day), 6 years(running 24hr per day). Warranty 1 year, 24 hours online after-sales servies team
7 Environment friendly refrigerant R410a/R407c/R134a, at least using R22
8 Plywood export box packing
9 OEM available
     Product Description  
Air-cooled water chiller parameters(output tem 5ºC)
 
Model UNIT WD-T  
3AC/S 5AC/S 6AC/S 8AC/S 10AC/S 12AC/S 15AC/S 20AC/S 25AC/S 30AC/S
Cooling capacity Btu 28865.52 46676.16 59780.40 72505.00 97787.92 110548.80 144737.04 202092.76 221029.36 289405.84
RT 2.4 3.89 5.28 6.04 8.14 9.20 12.05 16.83 18.40 24.10
Kw 8.46 13.68 18.60 21.25 28.66 32.40 42.42 59.23 64.78 84.82
×10³Kcal/h 7.23 11.74 15.99 18.32 24.65 27.83 36.60 51.02 55.65 73.05
Total Power KW 3.25 5.30 6.06 8.10 10..2 12.23 16.35 19.30 22.05 30.26
Total Current A 5.33 9.06 11.40 14.71 18.05 20.54 29.36 37.43 40.29 56.71
Compressor Qty 1 1 1 1 1 1 1 1 2 2 2.00
Input power KW 2.62 4.35 5.10 6.51 8.56 9.62 13.38 16.32 19.15 26.52
Operation Current A 4.70 8.10 9.91 12.70 16.00 17.70 25.90 32.60 35.00 51.70
Condenser Type Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger  
Fans Input power Kw 0.26 0.52 66.00 0.96 0.96 1.14 1.60 1.52 1.52 2.24
Water Pipe Connection Lnch 0.65 1" 2.00 2" 2" 2.8" 3.5" 4.8" 4.8" 5"
Evaporator Type Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger  
Freezing water Flow L/min 24.00 38.70 60.00 60.70 81.70 92.40 121.20 168.80 184.80 242.40
Water pipe connection Lnch 1" 1" 1" 2" 2" 2" 2" 2.5" 2.5" 3"
Freezing Water Pump Type High efficiency,low noise  
Input Power Kw 0.39 0.58 0.78 0.78 0.78 1.53 1.53 1.53 1.53 1.53
Input Current M 0.95 1.28 1.36 1.58 13.00 3.50 3.50 3.50 3.50 3.50
Lift of Outside of Machine Bar 15" 20" 22" 22" 20" 17" 25" 24" 18" 18"
Flow rate L/min 100.00 100.00 100.00 200.00 200.00 200.00 360.00 360.00 650.00 650.00
Refrigerant Type   R22/R134A/R407C/R410A/R507/R404  
Water tank Indicating Volume Liter 85.00 90.00 60.00 190.00 190.00 190.00 210.00 255.00 255.00 255.00
Safety protection High and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc.  
Dimensions (L*W*H) Length Mm 1150 1150 1415 1505 1505 1505 1755 2060 2060 2820
Width Mm 740 740 550 850 850 850 900 1025 1025 1025
High Mm 1375 1375 1000 1475 1475 1550 1780 1910 1910 2010
Total Weight KG 130.00 200' 230' 350' 350" 400" 420" 520" 735" 1035"
Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements.     Air-cooled chiller parameters(output tem -5ºC)
 
Air cooled chiller Model  UNIT WD-T  
3AC/SM1 5AC/SM1 6AC/M1 8AC/SM1 10AC/SM1 12AC/SM1 15AC/S M1 20AC/S M1 25AC/S M1 30AC/S M1
Cooling capacity Btu 17401.20 26681.84 29697.36 42513.52 61279.52 68717.68 89189.68 114165.52 136650.60 178447.60
RT 1.45 2.22 2.63 3.54 5.10 5.72 7.43 9.51 11.38 14.86
Kw 5.10 7.82 9.24 12.46 17.96 20.14 26.14 33.46 40.05 52.30
×10³Kcal/h 4.38 6.74 7.95 10.70 15.46 17.28 22.50 28.80 34.50 44.98
 Total Power KW 3.40 5.32 7.42 8.40 10.50 12.52 16.50 20.40 22.83 30.56
Total Current A 5.33 9.06 11.50 14.71 18.05 20.54 29.36 37.43 40.29 56.71
       Compressor  Qty 1 1 1 1 1 1 1 1 2 2 2.00
Input power kw 2.78 4.30 6.64 8.83 9.92 13.46 17.40 19.83 26.85 20.30
 Operation Current A 4.84 8.39 12.72 15.86 17.50 24.05 29.59 35.00 48.09 36.20
Condenser Type Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger  
Fans Input power kw 0.26 0.51 66.00 0.96 0.96 1.14 1.60 1.52 1.52 2.24
Water Pipe Connection lnch 0.65 1" 2.00 2" 2" 2.8" 3.5" 4.8" 4.8" 5"
  Evaporator  Type   Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger  
  Freezing water Flow L/min 15.70 24.30 60.00 38.70 55.80 62.30 81.30 104.00 111.50 124.50
Water pipe connection lnch 1" 1" 1" 2" 2" 2" 2" 2.5" 2.5" 3"
Freezing Water Pump Type  High efficiency,low noise  
Input Power Kw 0.39 0.58 0.78 0.78 0.78 1.53 1.53 1.53 1.53 1.53
 Input Current m 0.95 1.28 1.36 1.58 13.00 3.50 3.50 3.50 3.50 3.50
Lift of Outside of Machine Bar 16" 21" 17" 17" 16" 18" 26" 25" 25" 19"
 Flow rate l/min 100.00 100.00 100.00 200.00 200.00 200.00 360.00 360.00 650.00 650.00
Refrigerant  Type   R22/R134A/R407C/R410A/R507/R404  
    Water tank Indicating Volume Liter 85.00 90.00 60.00 190.00 190.00 190.00 210.00 255.00 255.00 255.00
Safety protection   high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc.  
Dimensions (L*W*H)  Length mm 1150 1150 1415 1505 1505 1505 1755 2060 2060 2820
Width mm 740 740 550 850 850 850 900 1025 1025 1025
  High mm 1375 1375 1000 1475 1475 1550 1780 1910 1910 2010
 Total Weight KG 130.00 200' 230' 350' 350' 410' 420' 540' 735.00 1035.00
Note:
1, the table refrigeration conditions: freezing glycol water inlet temperature 0 ºC, cold water temperature -5 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, this series of units used in low temperature conditions, to use 25% of the glycol for antifreeze coolants;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa);
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements.   Company Information     Packaging & Shipping      
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628