industrial chiller units Winday Industrial is a professional industrial water chiller manufacture in Shanghai, China. Successfully passed ISO9001 certification, CE certification, and has been successfully registered trademark "WINDAY".
Water chiller STRONG POINTS:
1 | Chiller compressor brand is Copeland USA.Scroll compressor. Or Danfoss/Daikin/Sanyo optional is customer appointed |
2 | Evaporator is plate type or copper shell and tube type,copper tube wall thickness is 0.7mm |
3 | Condenser is Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger |
4 | Pump and water systems are stainless steel SUS304 |
5 | High quality level electronic parts, Schneider/Siemens/LS |
6 | Designed chiller running life 10 years(running 8hr per day), 6 years(running 24hr per day). Warranty 1 year, 24 hours online after-sales servies team |
7 | Environment friendly refrigerant R410a/R407c/R134a, at least using R22 |
8 | Plywood export box packing |
9 | OEM available |
Product Description
Air-cooled water chiller parameters(output tem 5ºC)
Model | UNIT | WD-T | |
3AC/S | 5AC/S | 6AC/S | 8AC/S | 10AC/S | 12AC/S | 15AC/S | 20AC/S | 25AC/S | 30AC/S |
Cooling capacity | Btu | 28865.52 | 46676.16 | 59780.40 | 72505.00 | 97787.92 | 110548.80 | 144737.04 | 202092.76 | 221029.36 | 289405.84 |
RT | 2.4 | 3.89 | 5.28 | 6.04 | 8.14 | 9.20 | 12.05 | 16.83 | 18.40 | 24.10 |
Kw | 8.46 | 13.68 | 18.60 | 21.25 | 28.66 | 32.40 | 42.42 | 59.23 | 64.78 | 84.82 |
×10³Kcal/h | 7.23 | 11.74 | 15.99 | 18.32 | 24.65 | 27.83 | 36.60 | 51.02 | 55.65 | 73.05 |
Total Power | KW | 3.25 | 5.30 | 6.06 | 8.10 | 10..2 | 12.23 | 16.35 | 19.30 | 22.05 | 30.26 |
Total Current | A | 5.33 | 9.06 | 11.40 | 14.71 | 18.05 | 20.54 | 29.36 | 37.43 | 40.29 | 56.71 |
Compressor | Qty | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2.00 |
Input power | KW | 2.62 | 4.35 | 5.10 | 6.51 | 8.56 | 9.62 | 13.38 | 16.32 | 19.15 | 26.52 |
Operation Current | A | 4.70 | 8.10 | 9.91 | 12.70 | 16.00 | 17.70 | 25.90 | 32.60 | 35.00 | 51.70 |
Condenser | Type | Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger | |
Fans | Input power | Kw | 0.26 | 0.52 | 66.00 | 0.96 | 0.96 | 1.14 | 1.60 | 1.52 | 1.52 | 2.24 |
Water Pipe Connection | Lnch | 0.65 | 1" | 2.00 | 2" | 2" | 2.8" | 3.5" | 4.8" | 4.8" | 5" |
Evaporator | Type | Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger | |
Freezing water Flow | L/min | 24.00 | 38.70 | 60.00 | 60.70 | 81.70 | 92.40 | 121.20 | 168.80 | 184.80 | 242.40 |
Water pipe connection | Lnch | 1" | 1" | 1" | 2" | 2" | 2" | 2" | 2.5" | 2.5" | 3" |
Freezing Water Pump | Type | High efficiency,low noise | |
Input Power | Kw | 0.39 | 0.58 | 0.78 | 0.78 | 0.78 | 1.53 | 1.53 | 1.53 | 1.53 | 1.53 |
Input Current | M | 0.95 | 1.28 | 1.36 | 1.58 | 13.00 | 3.50 | 3.50 | 3.50 | 3.50 | 3.50 |
Lift of Outside of Machine | Bar | 15" | 20" | 22" | 22" | 20" | 17" | 25" | 24" | 18" | 18" |
Flow rate | L/min | 100.00 | 100.00 | 100.00 | 200.00 | 200.00 | 200.00 | 360.00 | 360.00 | 650.00 | 650.00 |
Refrigerant | Type | | R22/R134A/R407C/R410A/R507/R404 | |
Water tank Indicating Volume | Liter | 85.00 | 90.00 | 60.00 | 190.00 | 190.00 | 190.00 | 210.00 | 255.00 | 255.00 | 255.00 |
Safety protection | High and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. | |
Dimensions (L*W*H) | Length | Mm | 1150 | 1150 | 1415 | 1505 | 1505 | 1505 | 1755 | 2060 | 2060 | 2820 |
Width | Mm | 740 | 740 | 550 | 850 | 850 | 850 | 900 | 1025 | 1025 | 1025 |
High | Mm | 1375 | 1375 | 1000 | 1475 | 1475 | 1550 | 1780 | 1910 | 1910 | 2010 |
Total Weight | KG | 130.00 | 200' | 230' | 350' | 350" | 400" | 420" | 520" | 735" | 1035" |
Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements. Air-cooled chiller parameters(output tem -5ºC)
Air cooled chiller Model | UNIT | WD-T | |
3AC/SM1 | 5AC/SM1 | 6AC/M1 | 8AC/SM1 | 10AC/SM1 | 12AC/SM1 | 15AC/S M1 | 20AC/S M1 | 25AC/S M1 | 30AC/S M1 |
Cooling capacity | Btu | 17401.20 | 26681.84 | 29697.36 | 42513.52 | 61279.52 | 68717.68 | 89189.68 | 114165.52 | 136650.60 | 178447.60 |
RT | 1.45 | 2.22 | 2.63 | 3.54 | 5.10 | 5.72 | 7.43 | 9.51 | 11.38 | 14.86 |
Kw | 5.10 | 7.82 | 9.24 | 12.46 | 17.96 | 20.14 | 26.14 | 33.46 | 40.05 | 52.30 |
×10³Kcal/h | 4.38 | 6.74 | 7.95 | 10.70 | 15.46 | 17.28 | 22.50 | 28.80 | 34.50 | 44.98 |
Total Power | KW | 3.40 | 5.32 | 7.42 | 8.40 | 10.50 | 12.52 | 16.50 | 20.40 | 22.83 | 30.56 |
Total Current | A | 5.33 | 9.06 | 11.50 | 14.71 | 18.05 | 20.54 | 29.36 | 37.43 | 40.29 | 56.71 |
Compressor | Qty | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2.00 |
Input power | kw | 2.78 | 4.30 | 6.64 | 8.83 | 9.92 | 13.46 | 17.40 | 19.83 | 26.85 | 20.30 |
Operation Current | A | 4.84 | 8.39 | 12.72 | 15.86 | 17.50 | 24.05 | 29.59 | 35.00 | 48.09 | 36.20 |
Condenser | Type | Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger | |
Fans | Input power | kw | 0.26 | 0.51 | 66.00 | 0.96 | 0.96 | 1.14 | 1.60 | 1.52 | 1.52 | 2.24 |
Water Pipe Connection | lnch | 0.65 | 1" | 2.00 | 2" | 2" | 2.8" | 3.5" | 4.8" | 4.8" | 5" |
Evaporator | Type | Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger | |
Freezing water Flow | L/min | 15.70 | 24.30 | 60.00 | 38.70 | 55.80 | 62.30 | 81.30 | 104.00 | 111.50 | 124.50 |
Water pipe connection | lnch | 1" | 1" | 1" | 2" | 2" | 2" | 2" | 2.5" | 2.5" | 3" |
Freezing Water Pump | Type | High efficiency,low noise | |
Input Power | Kw | 0.39 | 0.58 | 0.78 | 0.78 | 0.78 | 1.53 | 1.53 | 1.53 | 1.53 | 1.53 |
Input Current | m | 0.95 | 1.28 | 1.36 | 1.58 | 13.00 | 3.50 | 3.50 | 3.50 | 3.50 | 3.50 |
Lift of Outside of Machine | Bar | 16" | 21" | 17" | 17" | 16" | 18" | 26" | 25" | 25" | 19" |
Flow rate | l/min | 100.00 | 100.00 | 100.00 | 200.00 | 200.00 | 200.00 | 360.00 | 360.00 | 650.00 | 650.00 |
Refrigerant | Type | | R22/R134A/R407C/R410A/R507/R404 | |
Water tank Indicating Volume | Liter | 85.00 | 90.00 | 60.00 | 190.00 | 190.00 | 190.00 | 210.00 | 255.00 | 255.00 | 255.00 |
Safety protection | high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. | |
Dimensions (L*W*H) | Length | mm | 1150 | 1150 | 1415 | 1505 | 1505 | 1505 | 1755 | 2060 | 2060 | 2820 |
Width | mm | 740 | 740 | 550 | 850 | 850 | 850 | 900 | 1025 | 1025 | 1025 |
High | mm | 1375 | 1375 | 1000 | 1475 | 1475 | 1550 | 1780 | 1910 | 1910 | 2010 |
Total Weight | KG | 130.00 | 200' | 230' | 350' | 350' | 410' | 420' | 540' | 735.00 | 1035.00 |
Note:
1, the table refrigeration conditions: freezing glycol water inlet temperature 0 ºC, cold water temperature -5 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, this series of units used in low temperature conditions, to use 25% of the glycol for antifreeze coolants;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa);
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements. Company Information
Packaging & Shipping