High voltage HVC automatic reactive power compensation device
High voltage HVC automatic reactive power compensation device
High voltage HVC automatic reactive power compensation device
High voltage HVC automatic reactive power compensation device
High voltage HVC automatic reactive power compensation device
High voltage HVC automatic reactive power compensation device

1 / 4

High voltage HVC automatic reactive power compensation device

Get Latest Price
Send Inquiry
Model No. : HVC
Brand Name : CODO

Product description

  Product Description  The details show          High voltage HVC automatic reactive compensation device is the device which automatically adjusts reactive power and improves system reactive power according to grid and loading conditions. In the case of enough compensation capacity, it can improve system power factor to over 0.9. High voltage HVC automatic reactive power compensation device mainly consists controller, cabinet body, capacitor integrated protector, vacuum contactor, series electric reactor, parallel capacitor, discharge coil, zinc oxide arrester, isolation switch, fuse auxiliary equipment, electric relay, busbar, indicating instrument, high voltage insulator, steel frame, multi-door electrical and mechanical linkage locking device, etc. High voltage HVC automatic reactive power compensation device applies full-intelligence control and microcomputer inspection to optimize switch mode and ensure optimum operation for equipment control. Controller inspects grid power factor. When inspected reactive current value exceeds setting value, control high voltage vacuum contactor to input capacitor bank according to the control signal given by grid power factor. When loading reactive current value is under setting value, controller gives a control signal to make high voltage vacuum contactor cut off capacitor banks. Capacitor banks stop working. Above process is automatically controlled by controller with no need of artificial intervention. Follow compensation loading reactive power and improve loading power factor.   Operating environment   u  Ambient temperature: -25℃ ~+40℃   u  Maximum daily temperature difference: 25℃   u  Altitude: ≤2000m, customed available over 2,000m   u  Environment relative humidity: annual average value≤90%   u  Seismic intensity: 8 Richter scale   u  Pollution level: III   u  Installation method: indoor installation   Notes: The above using environment applies to the company’s standard product. We can conduct special design according to special environment.   Power supply condition   u  System Standard Voltage: 3kV, 6kV, 10kV   u  Maximum working voltage: 3.6kV, 7.2kV, 12kV   u  Rated frequency: 50Hz, 60Hz   u  Phase number: 3   u  Control power source: AC220V/10A or DC220V/10A   Technical indicators   u  Rated capacity: determined by user requirements or company’s measurement results   u  Single bank maximum capacity: 3KV: ≤1000Kvar; 6KV: ≤2000kvar; 10KV: ≤4000kvar   u  Grouping condition: grouping arbitrarily based on users’ actual requirements   u  Dynamic overload capacity: Long-time operation under 1.30 In (rated current). Over-current is the interaction result of harmonics and 1.1 Un (rated voltage). Long-time operation under 1.10 Un. Maximum operation of 30min under 1.15 Un every 24 hours.   u  Power factor: over 0.9 (set between 0.8 and 1)   u  Controlled pathway: 24 pathways   u  Respond time: ≤20ms   u  Reactance rate: 5%, 6%, 7%, 12%, 13%, 14%   u  AC sampling voltage: 100V, AC sampling current 0~5A   u  Switching delay: set according to users’ requirements   u  Protection grade: IP30 (can be designed according to users’ requirements)   Technical properties   u  Full digital control, realize real-time inspection and calculation of system reactive power content   u  Distinguish transformer operation modes automatically. Judge the operation condition of 2 busbars of substation. That’s to say, realize 2 busbars simultaneously independent control (separate array) and 2 busbars common control (parallel), or single busbar control (single array).   u  Apply “software electrical dog” circuit fault tolerance technology. It can automatically find fault programs and prevent “system crash” thoroughly   u  Unique “Hardware fault protection circuit” ensures no malfunction order resulted.   u  Be equipped with man-machine controller and have the properties of intelligent judgment, optimum control and fast responding. Realize full digital management and the check of many circuit operation parameters.   u   Protection functions of compensation controller are complete (overvoltage, undervoltage, open delta voltage, short circuit and over current, etc ).   u  Apply series electric reactor to prevent enlarging harmonic and protect capacitor safe operation.   u  Switch cabinet applies mechanical and electrical double locking device which meets 5-prevention requirements.   u  Controller contains RS485 and CAN general line interface, realizing data remote transmission.   Specifications model description   High voltage HVC automatic reactive power compensation device adopts three-phase common compensation and wye connection mode. It can be divided into following systems according to voltage level: 3kV system, 6kV system and 10kV system. Its specifications model is as follows:       HVC-B-10(or 6,3)/X-X series single cabinet model table  

No.

Specification and Model

Rated capacity (kvar)

Overall dimension (W×D×H)

Weight

(kg)

1

HVC-B-10/150-1

150

1200×1500×2400

1400

2

HVC-B-10/200-1

200

1200×1500×2400

1420

3

HVC-B-10/250-1

250

1200×1500×2400

1445

4

HVC-B-10/300-1

300

1200×1500×2400

1470

5

HVC-B-10/400-1

400

1200×1500×2400

1502

6

HVC-B-10/450-1

450

1200×1500×2400

1520

7

HVC-B-10/500-1

500

1200×1500×2400

1538

8

HVC-B-10/600-1

600

1200×1500×2400

1580

9

HVC-B-10/750-1

750

1200×1500×2400

1625

10

HVC-B-10/900-1

900

1200×1500×2400

1660

11

HVC-B-10/1050-1

1050

1200×1500×2400

1700

12

HVC-B-10/1200-1

1200

1200×1500×2400

1750

13

HVC-B-10/1500-1

1500

1300×1500×2400

1930

14

HVC-B-10/1800-1

1800

1600×1500×2400

2000

15

HVC-B-10/2400-1

2400

1600×1500×2400

2120

16

HVC-B-10/2700-1

2700

1600×1500×2400

2250

17

HVC-B-10/3000-1

3000

1600×1500×2400

2400

18

HVC-B-10/3600-1

3600

1600×1800×2400

2550

19

HVC-B-10/4000-1

4000

1600×1800×2400

2700

20

HVC-B-10/K

Control cabinet

1000×1500×2400

840

  HVC-B-10 (or 6, 3) /X-X series B-type high voltage HVC automatic reactive power compensation device is made up of a control cabinet and the single cabinet in the above table. The result is various capacities and groups.   Notes: Compensation capacity, switching level and overall size can be customized.   The engineering case        Technology        