High Precision 4-20ma Isolator 2 Wire Series Loop Conditioner Ic
High Precision 4-20ma Isolator 2 Wire Series Loop Conditioner Ic
High Precision 4-20ma Isolator 2 Wire Series Loop Conditioner Ic
High Precision 4-20ma Isolator 2 Wire Series Loop Conditioner Ic
High Precision 4-20ma Isolator 2 Wire Series Loop Conditioner Ic
High Precision 4-20ma Isolator 2 Wire Series Loop Conditioner Ic

1 / 4

High Precision 4-20ma Isolator 2 Wire Series Loop Conditioner Ic

Get Latest Price
Send Inquiry
Model No. :
Brand Name :

Product description

Detailed Product Description
Product Name: 4-20ma Loop Isolator Precision: High Precision
Isolation Voltage: 3000V Size: SIP12 Pin Compact Size
Applications: Electric Instrument Vin: 32VDC

 

High Precision 4-20ma Isolator 2 wire Series Loop Conditioner IC

 

ISO 4-20mA-E Series2-wire 4-20mA Current Loop Conditioner IC

 

ISO 4-20mA-E Series Active Load Two-wire 4-20mA Current Loop Isolation Transmitter IC is a kind of two-wire active 4-20mA sensor signal isolation regulator. It can convert active 4-20mA current signal into isolated passive control signal.The loop powered 4-20mA circuit achieves the perfect match between the sensor signal acquisition and the active load of analog input interface. It effectively solve the power conflict problem between the active 4-20mA current signal acquisition and the power supply in interface of two-wire loop powered circuits

 

 

Specifications:

 

● No need external power, two wire signal circuit power supply output

● Active 4-20mA signal acquisition,5-32V super wider input voltage range.

● High precision of 4-20mA measuring range(0.1,0.2) 

● Industrial grade temperature range:- 45℃ ~ + 85℃

● High linearity of 4-20mA signal transmission: non-linearity<0.1%

●3000V isolation voltage between active 4-20mA signal acquisition input and output.

● Active signal input, output can control the active load of electric current loop.

● SIP12 Pin compact size,  UL94V-0 standard antifoaming package

 

Sunyuan SIP12 package two wire 4-20mA signal isolation regulations and control IC: ISO 4-20mA-E. it is a two wire active sensor 4-20mA signal isolation regulator, belong to 4-20mA series product. It can convert input active 4-20mA current signal to output isolation passive control signal, which control two-wire power supply(anti-explosion method) 4-20mA loop circuit. Then realize the matching of the sensor signal acquisition with the active load of analog input interface. It effective solves the power conflict problem between the acquisition active 4-20mA current signal and two wire electrical current loop power loops receive.

 

ISO 4-20mA-Eadopt high efficiency return circuit stealing electricity technology, based on which the ic do not need powered by independent power. The advantage to use two wire return circuit power supply output mode can spare two power wires, simplify user’s design also cut down user’s wiring cost. This IC internally includes current signal modulation circuit, signal coupling isolation changing circuit. Pimping input equivalent resistor make the IC able to acquisition current signal from the sensor output loop voltage up to wide range (5-32V DC), to meet user’s requirement that non-external power and with  long-term undistorted transmission.

 

ISO 4-20mA-E  the output designed aim to 24VDC and series wound two wire power loop circuit of sample resistance (two wire meter), it match with the industrial common analog input interface board (Host computer),PLC,DCS or other meters analog input interface board that include active load.. It can meet industrial temperature, humid,, vibrate severe environment requirement. Easy use, only with a external connection 10KΩ multitier potentiometer to gain adjust then can realize two wire 4-20mA signal isolation, transmission and acquisition control.

 

 

Applications:

 

● Two wire active load signal match and control

● PLC/DCS spot analog signal isolation/acquisition.

● GND circulation isolation and interference suppression.

● Matching sensor signal and analog input and output interface

● Analog signal data acquisition and long-term undistorted transmission.

● Electric instrument, Armamentarium monitor isolation safety barrier.

●Sensor 4-20mA signal’s acquisition isolation, regulation and transmission.

 

 

Product Maximum rating

 

(Long time under maximum rating working will affect product’s use life, beyond maximum rating will cause irreparable damage.)

 

Continuous Isolation Voltage                                            3KVDC/rms                 

Vin                                                                                       32VDC

Junction Temperature                                                   - 45℃ ~ + 85℃

Lead Temperature     (<10S)                                          +300℃

Output Short to Common                                                 continuous        

 

 

General Parameter:

 

Precision and non-linearity ---------- 0.1,0.2

Return difference  ---------- < 0.5%

Power supply---------- non

isolation  ---------- signal input/output

Work temperature---------- -20 ~ +70℃ 

Insulation resistance ---------- ≥20MΩ

Work humidity---------- 10 ~ 90% (non-condensation)

Withstand voltage ---------- 3KV(60HZ / S),leakage current 1mA

Storage temperature---------- -20 ~ +70℃   

Impact resistance voltage---------- 3KV, 1.2/50us(Peak)

Storage humidity---------- 10 ~ 95% (non-condensation)

 

 

Technical Parameter:  

   

Parameter

Condition

Min

Typical

Max.

Unit

Isolation voltage  AC,50Hz

Insulation resistance

Leakage current

10S

 

240Vrms,50Hz

3000

 

10¹²‖1

0.5

 

VDC

Ω‖Pf

uA

Temperature Drift

Non-linearity

 

 

±50

±0.2

±100

±0.5

PPm/℃

%FSK

Load capacity

24VDC

 

750

 

Ω

Input signal voltage range

 

5

24

36

VDC

Output signal voltage range

RL:250Ω

13

24

36

VDC

Output linear range

Output current  Io

 

 

 

0.5

4

 

24

40

mA

mA

Output ripple wave

 

 

10

20

mV

Frequency response(small signal bandwidth)

Io=20mA

 

100

 

Hz

 

 

IC Pin Description:

 

 High Precision 4-20ma Isolator 2 wire Series Loop Conditioner IC

Signal input+

Signal input-

NC

Gain adjust 1

Gain adjust 2

Current output+

Loop circuit power+

 

NC

Iin

GND

NC

Adj 1

Adj 2

Io+

V+

NC

1

2

3~7

8

9

10

11

12

 

 

 

Product outline and PCB fabric swatch dimension:

 

DIN 3 Install dimension

 

Typical Application:

 

High Precision 4-20ma Isolator 2 wire Series Loop Conditioner IC

 

Active load two wire 4-20mA signal isolation control application wiring

 

DIN3 4-20mA-E signal isolation control application wiring

 

 

Application E.G. 1

 

ISO4-20mA-E isolation two wire sensor 4-20mA active signal input, passive signal output (two wire signal circuit power supply output)

 


High Precision 4-20ma Isolator 2 wire Series Loop Conditioner IC

 

E.G. 2:

 

ISO 4-20mA-E isolation Four-wire sensor 4-20mA active signal input, passive signal output. (two wire active load circuit power supply output)

 High Precision 4-20ma Isolator 2 wire Series Loop Conditioner IC  

E.G.3

 

ISO 4-20mA-E isolation Four-wire sensor 4-20mA active signal input, passive signal output. (Two wire signal circuit power supply output)    

 Output with external protect circuit application scheme.


High Precision 4-20ma Isolator 2 wire Series Loop Conditioner IC  

Product outline install method reference:

The usual connection solution for industrial sensor and instruments (ISO 4-20mA) Series

1,Two wire sensor 4-20mA active signal and active load connection


High Precision 4-20ma Isolator 2 wire Series Loop Conditioner IC

 

2,Two wire sensor4-20mA active signal and passive load connection

 

3,Two wire sensor 4-20mA passive signal and active load connection

 

4,Two wire sensor 4-20mA passive signal and passive load connection

 

 

FAQ:

 

1. When was Sunyuan established? How long has it been in this industry?

 

Answer: Sunyuan was established on Year 2002 by our General Manager Yu Guang Yuan.we have been in this industry for ten years. All our products are R&D by our technical team and win more than 10 patents. In year 2011 was rated National High and New Technology Company.

 

2. What qualification do you have?

 

Answer: According to the different markets' demands, Sunyuan has got the CE certificate; the product materials meet the ROHS requirements. And have approved ISO9001:2008 International Quality Certification in 2012

 

3. What’s your MOQ? Whether can get samples?

 

Answer: NO MOQ limit for EXW.

       Samples are available; some parts can provide free samples.

 

4. What’s the lead time?

 

Answer: 3-5 days.

 

5. What’s the guarantee?

 

Answer: Five years. And within two years, any quality problem can provide maintain and replace.

 

6. Any Foreign distributors?

 

Answer: Sunyuan has distributors located in US, France, Brazil and India.

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628