1 / 2
Model No. : | MS-60-8 |
---|---|
Brand Name : | MFW |
Product description
Mode | MS-60-5 | MS-60-12 | MS-60-15 | MS-60-24 |
Performance | ||||
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage tolerance | ±2% | ±1% | ±1% | ±1% |
Rated output current | 12A | 5A | 4A | 2.5A |
Output current range | 0-12A | 0-5A | 0- 4A | 0-2.5A |
Ripple and noise | 100mVp-p | 50mVp-p | 50mVp-p | 50mVp-p |
Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 60W | 60W | 60W | 60W |
Efficiency | 75% | 85% | 85% | 86% |
Adjustable range for DC voltage | +10,-5% | ±10% | ±10% | ±10% |
AC input voltage range | 110~264VAC 47~63Hz; 155~370VDC | |||
Input current | 0.55A/230V | |||
AC dash current | 30A/230V | |||
Leakage current | <0.5mA/240VAC | |||
Overload protection | 105%~150% Type: pulsing hiccup shutdown reset: auto recovery | |||
Over-voltage protection | ………………… | |||
High-temperature protection | …………………. | |||
Temperature coefficient | ±0.03%/℃(0~50℃) | |||
Startup .rise .retention time | 200ms 100ms 30ms | |||
Vibration | 10~500Hz, 2G 10min/1 cycle , Period for 60 min , Each axes | |||
With standard voltage | Input and output internal :1.5KvAC input and enclosure : 1.5KvAC output and enclosure: 0.5KvAC | |||
Isolation resistance | Input and output internal: input and enclosure. Output and enclosure: 500VDC/100MΩ | |||
Working temperature and humidity | -10℃~+60℃(Refer to output diagram cech,20%~90%RH | |||
Store temperature and humidity | -20℃~+85℃, 10%~95%RH | |||
Overall dimension | 110×77×35mm | |||
Weight | 245g | |||
Safety standards | UL 1012 TUV EN6050(IEC,UL1950) Approved | |||
EMC standards | CISPR22(EN55022),IEC801-2,3,4IEC555 -2 Verification | |||
Note : 1. The testing condition for the parameter above is : 230VAC input ,rated load, 25℃ 70%Rh. Temperature. | ||||
2. Error, include the setting error, line stability and load stability . | ||||
3. Wave test: adopt “A12” double wire for 20MHz, and 0.1UF & 47UF capacitor short-circuit for interrupting. | ||||
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. | ||||
5. Load stability test: The load is from 0% to100% |