1 / 6
Model No. : | LG200 |
---|---|
Brand Name : | xinyang |
Product description
Xinyang LG200 Specification: | |
the steam consumption for the heating | ≥650kg / hour |
Weight (unloaded) | 25000kg (approx.) |
Chamber – Over all dimensions | 13.00m long x 2.50m wide x3.30m high (AISI 304 S/S) |
Vapour Condenser Capacity | 440 kg in a hour |
Number of shelves | 480 trays |
Usable Shelf Area (m2) | 200 m2 |
Ice Capacity (kg) | 440 kg/h |
Shelf Dimensions | 560*680*35mm |
Shelf Spacing (mm) | 35mm |
Shelf Temperature | -20oC to +60oC |
the condenser temperature | - 45C |
Low temperature model: shelf freezing to -35oC and vapour condenser temperature -45oC | |
Free distance between heating plates | 75mm |
Heating medium | Hot water |
Heating type | Double-sided radiation |
Heating medium, max. temperature | 130 C |
heating flange | ≥5 C / min speed |
the speed of cooling | 7a min (from 20C to – 40C without load) |
Cooling medium | Ammonia, freon |
Material of heating plates | Aluminum |
Sublimation(max) | 2.5kg/m2h |
Sublimation(average) | 1.5kg/m2h |
Power Requirement | 380VAC/50Hz,3phase,100KW(no including refrigerator) |
Vacuum | 133Pa (working 50pa ~ 133Pa) |
Material of vapor trap | Stainless steel |
water for bathing | automatic de-icing , no need water |
Specification Model | LG30 | LG50 | LG75 | LG100 | LG125 | LG200 | |
Heating Areas(m2) | 30 | 50 | 75 | 100 | 125 | 200 | |
Numbers of Vapor trap | Single | Double | Double | Double | Double | Double | Double |
Trapping Capacity | >400kg/batch | >66kg/hr | >110kg/hr | >165kg/hr | >220kg/hr | >275kg/hr | >440kg/hr |
Heating Medium | Water&electric | Water&Steam | Water&Steam | Water&Steam | Water&Steam | Water&Steam | Water&Steam |
Heating Mode | Double side radiation | ||||||
Temperature range of Heating plates | <95C | Normal Temp.~+130C | |||||
Vacuum Pressure (Pa) | 20~133 | ||||||
Need Refrigeration Capacity (t0=-4C,tk=-35C) (Kw) | 55 | 80 | 120 | 160 | 200 | 320 | |
Consumption of Steam (kg/h) | None | 150 | 200 | 280 | 340 | 400 | 690 |
Electric Power Supply (Kw) | 75 | 40 | 43 | 63 | 69 | 85 | 115 |
Tray Numbers | 78 | 80 | 120 | 180 | 240 | 300 | 480 |
Loading Raw Material | >390 | >400 | >600 | >900 | >1200 | >1500 | >2400 |