Fonton engine genset
Fonton engine genset
Fonton engine genset
Fonton engine genset
Fonton engine genset

1 / 3

Fonton engine genset

Get Latest Price
Send Inquiry
Model No. : GFI-40KW
Brand Name : Pengjie

Product description

Foton Diesel Generator/Diesel Generator Set/Generators Power From 20kVA up to 40kVA, with compacted structure and simple operation and the feature of environmental friendly, high reliability and fuel efficiency.

As small power genset, it is widely used in the area of industry, railway, construction and so on.

Engine and alternator mounted on the same frame steel skid.
Built-in damper for anti-vibration.
Small size, low weight, easy to operate, installation and maintenance.
World famous brand AC alternator: Stamford, Marathon, Leroy Somer, etc.
Advanced and reliable control module: Key start, Auto start, Remote control by PC with RS232/485
Full range protect function and alarm shutdown feature.
ATS, Base Fuel Tank as Options

Control Systems

Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears.

LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory.

LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets.

General Data Sheet
Model 4JB1 4JB1T 4JB1 4JB1T
1500  rpm 1800 rpm
Engine Type Water-cooled, In line, 4 cylinder, direct injection
Rated Power (kW) 24 28 28 34
Standby Power(kW ) 26 31 31 37
Induction System Naturally Aspirated Turbocharged Naturally Aspirated Turbocharged
Bore (mm)× Stroke (mm) 93× 102 93× 102 93× 102 93× 102
Displacement (L) 2.771 2.771 2.771 2.771
Piston Speed (m/s) 5.1 5.1 6.12 6.12
Compression Ratio 18.2: 1 18.2: 1 18.2: 1 18.2: 1
Steady Speed Drop ≤ 5% ≤ 5% ≤ 5% ≤ 5%
Fuel Consumption (L/h) 5.6 6.4 6.5 7.8
    Foton-Isuzu Diesel Generator/Diesel Generator Set/Generators Power From 20kVA up to 40kVA, with compacted structure and simple operation and the feature of environmental friendly, high reliability and fuel efficiency.

As small power genset, it is widely used in the area of industry, railway, construction and so on.

Engine and alternator mounted on the same frame steel skid.
Built-in damper for anti-vibration.
Small size, low weight, easy to operate, installation and maintenance.
World famous brand AC alternator: Stamford, Marathon, Leroy Somer, etc.
Advanced and reliable control module: Key start, Auto start, Remote control by PC with RS232/485
Full range protect function and alarm shutdown feature.
ATS, Base Fuel Tank as Options

Control Systems

Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears.

LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory.

LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets.

General Data Sheet
Model 4JB1 4JB1T 4JB1 4JB1T
1500  rpm 1800 rpm
Engine Type Water-cooled, In line, 4 cylinder, direct injection
Rated Power (kW) 24 28 28 34
Standby Power(kW ) 26 31 31 37
Induction System Naturally Aspirated Turbocharged Naturally Aspirated Turbocharged
Bore (mm)× Stroke (mm) 93× 102 93× 102 93× 102 93× 102
Displacement (L) 2.771 2.771 2.771 2.771
Piston Speed (m/s) 5.1 5.1 6.12 6.12
Compression Ratio 18.2: 1 18.2: 1 18.2: 1 18.2: 1
Steady Speed Drop ≤ 5% ≤ 5% ≤ 5% ≤ 5%
Fuel Consumption (L/h) 5.6 6.4 6.5 7.8
   
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628