Specifications high viscosity petroleum flow meter
1. high precision
2. Long life
3. stable performance
4.suitable for high viscosity
flow meter for petroleum process of high viscosity Summary LBTC positive displacement rotary vane flow meter belongs to positive displacement meter and is one of the most accurate measuring meters for measuring liquid of modern industry. The flow meter has stable performance and is insensitive to flow state change of upstream medium and change of medium viscosity. It has high measuring accuracy,good applicability and long life. Now it has widely used for every field such as process control of modern industry and trade settlement, etc. Operation Principle
There are two or three couples of rotary vanes, they slide radially along grooves in the barrel-type rotor. With
the action of flowing pressurized fluid, pushing the rotary vanes and the rotor rotates around its axis. Rotary vanes
continuously divide the flowing fluid into an individual volume, using drive gear and counting mechanism calculate and indicate the total delivery of the fluid. The process as follows: when the rotary vanes are at the state as figure 1.1,vane A and D stretch out from the rotor and contact the inwall of measuring chamber while vane B and C retract back completely into rotor. With the fluid entering into the meter, it pushes the vanes and the rotor rotating clockwise. When the rotor and vanes run 1/8 circle, the vanes stop at the position as shown in figure 1.2, vane A stretches completely, vane D begins to retract back, vane C is still in completely contraction state, while vane B begins to stretch out. When the rotor and the vanes run a 1/4 circle, the vanes are in the positions as shown in figure 1.3. The vane A and B both completely stretch out, the space which is composed of the two vanes, rotor, the meter case bore, the upper cover and lower cover is full of measuring fluid. When the rotor and the vanes are in the position as shown in figure 1.4, the fluid in the space begins to be released with the vane A withdrawing gradually. Meanwhile, the vane C begins to stretch out, another new exactly measuring fluid volume between the vane B and C begins to form gradually. So when four vanes rotate around the whole circle is 4 times of volume. ( the meter has three pairs vanes, 6 space volumes will be drained) it realizes fluid measurement.
Main technical parameters 1.Intrinsic Error:0.2%;0.5% 2.Nominal Diameter (mm):25mm;50mm;80mm;100mm;150mm;200mm;250mm;300mm; 3.Nominal Pressure:2.5MPa;4.0MPa; 6.4MPa;
4.Flow Rate Range:
Nominal Diameter | 25 | 50 | 80 | 100 | 150 | 200 | 250 | 300 |
Intrinsic Error % | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 |
Min. Flow m3/h | 3 | 1 | 8 | 5 | 25 | 18 | 35 | 25 | 60 | 40 | 100 | 80 | 120 | 110 | 300 | 200 |
Max. Flow m3/h | 6 | 8 | 20 | 35 | 65 | 80 | 90 | 115 | 120 | 150 | 180 | 240 | 350 | 550 | 900 | 1000 |
5.Operation Temperature: -20.C ~ +250.C;(special temperature should indicate.)
6.Fluid Viscosity: 0.6~500mPa.s ( kinematic viscosity)
7.Pressure loss: no more than 0.1MPa(such as nominal diameter is DN80)
8.Min. Indication Unit: For equipped with mechanical header, subject to the model of selected header.
For equipped with intelligent header: 0.001m3
9. Integrated Flux: For equipped with mechanical header, subject to the model of selected header.
For equipped with intelligent header: 99999.9999 m3
10. Coefficient of theoretical instrument: only for equipped with intelligent meter.
Nominal diameter DN | 25 | 50 | 80 | 100 | 150 | 200 | 250 | 300 |
Coefficient of theoretical instrument N/L | 18.868 | 6.993 | 3.657 | 2.357 | 1.634 | 1.483
| 0.841 | 0.563 |
Model Selection Table
Model | Code | Code meaning |
LBTC- | | Positive displacement rotary vane flow meter |
| 25 | | Nominal diameter:DN25mm |
50 | | Nominal diameter:DN50mm |
80 | | Nominal diameter:DN80mm |
100 | | Nominal diameter:DN100mm |
150 | | Nominal diameter:DN150mm |
200 | | Nominal diameter:DN200mm |
250 | | Nominal diameter:DN250mm |
300 | | Nominal diameter:DN300mm |
| Q | | House material: nodular cast iron |
C | | House material: carbon steel |
P | | House material: 304 |
| 2.5 | | Nominal Pressure: 2.5MPa |
4.0 | | Nominal Pressure:4.0MPa |
6.3 | | Nominal Pressure:6.4MPa |
| JX | | With mechanical counter, local indication. |
BS | | With mechanical counter, remote signal transmitted with pulse transmitter |
ZN1 | | With intelligent instrument, local indication; remote signal transmitted with pulse transmitter. |
ZN2 | | With intelligent instrument, local indication with 4~20mA signal output. |
ZN3 | | With intelligent instrument, local indication with 4~20mA signal output and remote signal transmitted with pulse signal transmitter |
| i | Intrinsically safe: ia IICT5 (for intelligent meter or pulse signal transmitter) |
d | Explosion isolation: d IIBT4 (for intelligent meter or pulse signal transmitter) |
LBTC- | | | | | | |
1. counter 2. transmitter 3. precision adjusting mechanism
4. flow transmitter 5.external precision adjustment device