Flame-retardant Flat Cable FFC Flexible Flat Cable
Flame-retardant Flat Cable FFC Flexible Flat Cable
Flame-retardant Flat Cable FFC Flexible Flat Cable
Flame-retardant Flat Cable FFC Flexible Flat Cable
Flame-retardant Flat Cable FFC Flexible Flat Cable
Flame-retardant Flat Cable FFC Flexible Flat Cable
Flame-retardant Flat Cable FFC Flexible Flat Cable

1 / 5

Flame-retardant Flat Cable FFC Flexible Flat Cable

Get Latest Price
Send Inquiry
Model No. : YVFD
Brand Name : SINYU

Product description

Specifications 1.20 years exprience cable manufacturer

2.With CE/CCC/ISO 9001/ 9004/ IEC

3.OEM Service

4.Many kinds of size, can custom-made

Flame-retardant Flat Cable FFC Flexible Flat Cable   Product Description     Features and Applications   This product is used in cable hanging, drawing and installation for field line, electric appliance and instrument electronic equipment and automation devices for electric power,chemical, metallurgy, open port, goods yard and mine etc.As silicone rubber and butyronitrile PVC from GE company of USA and domestic modified Model 271 silicone rubber are respectively used in insulation and coating materials, the product is especially soft, easily folded and movable, smooth and unbending, It is one of products solemnly recommended by our company.   Executive Standard Q/AHXYLY04-2009.equivalent to IEC245-3 standard.   Operational Performances (1) AC rated voltage U0/U:6/10kV(only limited in silicone rubber flat cable) and 0.6/1kV; (2) Maximum operating temperature of cable core: butyronitrile flat:-40°C~105°C and -40°C~135°C; (3) Core does not break after 50000 bending. (4) Bending radius: no less than 10 times of cable perimeter.   Technical Data   1.Maximum D.C resistance of each sectional cable core at 20°C Section(mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 Resistance Ω/km 13.3 7.98 4.95 3.30 1.91 1.21 0.78 0.554 0.386 0.272 0.206   2.Minimum D.C resistance of each sectional cable core at 105°C Section(mm2) 1.5 2.5 4 6-10 16-70 95-150 180 Resistance Ω/km 10 9 8 7 6 5 4   3.Amendatory coefficient of flow carrying at different ambient temperature -20°C -15°C -10°C -5°C -0°C 5°C 10°C 15°C   1.45 1.40 1.40 1.30 1.25 1.20 1 .15 1 .10 20°C 25°C 30°C 35°C 40°C 45°C 50°C 45°C 1.05 1.0 0.94 0.885 0.815 0.745 0.666 0.577   4.Voltage resistant experiment of finished cable:As per IEC502(1994) Standard Rated voltage 0.6/1kV and below, not breakdown after A.C 50Hz, 2kV, test for 5 min;Rated voltage 6kV and below, not breakdown after D.C 25kV,immersion at 20°C test for 1h   5.Minimum tensile strength of insulation and coating: 10N/mm2; Minimum breakage elongation rate: 150%; Minimum elongation rate at -40°C:20%.   Basic Model and Designation   Table 1 Model and Designation   Type Designation   YVFB Multi-strand fine Cu intertwisted PVC insulation, butyronitrile PVC sheath flat and soft cable   ZR-YVFB Multi-strand fine Cu intertwisted flame-retardant 105°C PVC insulation, butyronitrile PVC sheath flat and soft cable   ZR135-YVFB Multi-strand fuse Cu intertwisted flame-retardant 135°C PVC insulation, butyronitrile PVC sheath flat and soft cable   YGCB Multi-strand fine Cu intertwisted heavy duty silicone rubber insulation, PVC sheath flat and soft cable   YGCFB Multi-strand fine Cu intertwisted butyronitrile PVC insulation, heavy duty silicone rubber sheath flat and soft cable   YGCF4B Multi-strand fine Cu intertwisted insulation, heavy duty silicone rubber sheath flat and soft cable   Table 2 Code and Definition   Code ZR ZR135 Y G C F F4 B   Definition Flame-retardant 105°C PVC Flame-retardant 135°C PVC Mobile Silicone rubber Heavy duty Butyrouitrile PVC Teflon Flat   Schematic Diagram of Structure   Specification and reference data Marking Examples   Example 1. This model of cable is shielded with copper wire or plated tin copper wire intwined without labeling model. Remarks shall noted after the model if shielding is needed. e.g: YGCPB 4 X 1.5 shielded each wire;   Example 2. This model of cable core is available with multi-strand fine copper wire intertwisted and multi-strand tin fine copper wire intertwisted. Example 3. This model of cable can be made into compound cable but shall be shielded mutually and remarks shall be noted as: YGCFB 3 X 16+6 X 4 totally shielded, 6 cores section 4mm2, with each wire shielded. Example 4. Those rated voltage of 0.6/1kV and below 0.6/1kV may not be labeled for this model of cable. Endured voltage shall be noted for this model of cable if rated voltage is 6/10kV e.g. YGCB(6kV) 3 X 50; Example 5 This model of cable can be designed and customed as per professional requirements by user.   FAQ   Any questions please do not hesitate to contact me through:                       Skype:daisy.chow86             Trademanager: sinyucable     Packaging & Shipping  

Packaging Detail:

international wooden drums   or according to your requirement.

Delivery Detail:

In 15days or as the quantity   you required

    Our Services    1.Free samples can be afford if needed. 2.2 years warranty after selling       Company Information     
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628