Model No. : SUN-600K
Brand Name : Sunbright

Product description

Specifications Standard: 3/5 lead ECG,RESP,SpO2,NIMP,TEMP,PR,Network

Optional:2-IBP,Recorder,12 lead ECG,ETCO2

Introduction:  This equipment can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP. It integrates parameter measuring module, display and recorder in one device to form a compact and portable device. At the same time, its built-in replaceable battery provides convenience for patient moving. Features * 12.1"High brightnees TFT LCD display *  Portable ,streamline handle design *  Big figure display  *  ECG Waveforms of 7-lead displayed in one screen *  96-hour tabular and graphic trends & date storage     *  Compatible and self identify 3-lead and 5-lead ECG cable *  NIBP dual Over Pressure Protection *  Isolated floating,anti defibrillation protected and anti high-frequency   interference 
  Standard parameter & configuration 3/5 lead ECG,RESP,SpO2,NIMP,TEMP,PR,Network   Optional parameter & configuration 2-IBP,Recorder,12 lead ECG,ETCO2 Performance:

ECG

 

Lead Mode 3-lead and 5-lead are optional

Lead Selection I, II, III, avR, avL, avF, V

Wave 5-lead: 2 channels

3-lead: 1channel

Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV

HR Measuring and Alarm Range

Range 15 ~ 300 bpm 

Accuracy ±1% or ±1bpm, which is greater

Alarm Accuracy ±2bpm

Resolution 1 bpm

CMRR

 

Monitor ≥ 100 dB

Surgery ≥ 100 dB

Diagnosis ≥ 60 dB

Bandwidth

 

Surgery 1 ~ 20 Hz(+0.4dB,-3dB)

Monitor 0.5 ~ 40 Hz(+0.4dB,-3dB)

Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB)

Calibration Signal 1 mV (Vp-p), ±5%  Accuracy

   

NIBP

Method Oscillometry

Mode Manual, Auto, continuous 

Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90/120/240/480/960 Min

Measuring Period in Continuous Mode 5 Min

Measuring and Alarm Range 10~270mmHg

Alarm Type SYS, DIA, MEAN

Resolution

 

Pressure 1mmHg

Cuff Pressure ±3 mmHg

Accuracy ±10% or ±8mmHg, which is greater

Over-pressure Protection:

Adult Mode 315±10 mmHg

Pediatric Mode 265±10 mmHg

Neonatal Mode 155±10 mmHg

SpO2

Measuring Range 0 ~ 100 %

Alarm Range 0 ~ 100 %

Resolution 1 %

Accuracy   70% ~ 100% ±2%

  0% ~ 69% unspecified

Pulse Rate(PR)

 

Measuring and Alarm Range 0~250bpm

Resolution 1bpm

Measuring Accuracy ±2bpm or ±2%, which is greater

Alarm Accuracy ±2bpm

TEMP

Channel dual-channel

Measuring and Alarm Range 0 ~ 50°C

Resolution 0.1°C

Accuracy ±0.1°C

Actualization Interval about 1 Sec.

Average Time Constant < 10 Sec.

Alarm responding Time ≤2min

EtCO2

Method Sidestream or Mainstream 
Measuring Range for CO2 0~150mmHg

Resolution for CO2:

0.1 mm Hg 0 to 69 mm Hg
0.25 mm Hg 70 to 150 mm Hg


Accuracy for CO2:  0 – 40 mm Hg ±2 mm Hg
                    41 – 70 mm Hg ±5%
                    71 – 100 mm Hg ±8%
                    101 – 150 mm Hg ±10%
                    Respiration Rate>80BPM ±12%
                    AwRR Range 2~150 rpm
                    AwRR Accuracy  ±1BPM

                    Apnea Alarm Available

IBP

Channel dual-channel

Label ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and Alarm Range -50~350 mm Hg
Resolution 1 mm Hg

Accuracy ±2% or 1mm Hg, which is greater