Model No. : composite insulator
Brand Name : TCI

Product description

Specifications rod composite insulator

1.Brand:TCI .

2.Portection systems.

3.High cantilever load.

4.Near dalian port.

Electrical fiberglass reinforcing rod composite insulator  Product Description     Welcome to visit our website, please send us your technical specifications or drawings on the email, then we will provide the offer to you as soon as possible. TKS.   Service Condition:   Ambient temperature                            -40°C~+40°C AC power supply frequency                        ≤100 HZ Earthquake intensity:                                 ≤8 Altitude                                                   ≤1500 m Maximum wind velocity                               ≤35 m/s       Electrical fiberglass reinforcing rod composite insulator
1. Power fittings of electrical composite insulator is connected with electric poles or wooden electrical poles.
2. ECR rod, reinforcing fiberglass rod used for electrical composite insulator and with high strength
3. silicone rubber high voltage composite insulator and composite insulator electric insulator is on hot sale.
4. FXBW-35KV,110KV,220KV,is under full production, and good quality composite insulator is under testing.
5. 10-35kv knitted composite insulator, Electrical fiberglass reinforcing rod composite insulator is new design.
6. composite insulator end fitting cap and pin insulator is a suspension or long rod type.
7. polymeric composite insulator is used for wooden electrical poles and power tower with power fittings.

Electrical fiberglass reinforcing rod composite insulator Parameter:
Insulator technical description Unit Value
Rated voltage kV

12KV,15kv,24KV,36KV,69KV,110kv,123KV,132KV

,245KV,300KV,400KV,500KV

Creepage distance mm

300mm,450mm,720mm,900mm,

1050mm,1116mm, 1260mm and above

 

Arcing distance mm according to section length and electrical parameter requirement
Specified Mechanical load(SML) KN

45KN.70KN,80KN,90kn,100KN,111kn

120KN,160KN,210KN,8KN, 10KN,12.5KN,16KN

Power frequency dry withstand voltage kV according to composite isolator drawing
Power frequency wet withstand voltage kV according to composite isolator specification
Lightning impluse withstand voltage pos. kV according to insulator used electrical environment
Lightning impluse withstand volt age neg. kV as per insulator standard and drawing 
    Packaging & Shipping       Our Services       Company Information     FAQ     Tips: Since we (TCI) have many different models and types,providing exact model or detailed technical specification in your inquiry will largely help us finding your a better solution within less time and reducing your communication cost.   Contact with me:Jeff Song 24Hours in Email me:song@tcipower.com Dalian Tucheng International Corp. Dalian Composite Insulator Corp. Tel:+86 411 82789881/82789882  Fax:+86 411 82789882 http://www.tcipower.com  