Electric Three Phase Energy Meter Test Bench with class 0.0
Electric Three Phase Energy Meter Test Bench with class 0.0
Electric Three Phase Energy Meter Test Bench with class 0.0

1 / 1

Electric Three Phase Energy Meter Test Bench with class 0.0

Get Latest Price
Send Inquiry
Model No. : XL-6300D
Brand Name : Xili
10yrs

Hangzhou , zhejiang, China

Visit The Store

Product description

Electric Three Phase Energy Meter Test Bench with class 0.05 / 0.1 High Accuracy

Description

The test bench accuracy class: 0.05/0.1

Reference standard energy meter:

XL 3100 three phase multi-functions precision power testing instrument

Accuracy class: 0.05 /0.1

MSVT(multi secondary voltage transformer) class: 0.02

Primary voltage: 180-300V (Normal Voltage: 240V)

Secondary voltage: 180-300V

Secondary VA rating: 15VA per winding

Insulation secondary to secondary: 500V, 50Hz, 60 seconds

Primary to secondary ratio accuracy: ±0.1% (typical)

Secondary to secondary ratio accuracy less than: ±0.02%

Secondary to secondary phase angle accuracy less than ±1 minute

Number of secondary output: 8~60channel

Voltage amplifier:

Output voltage range: 30-400V (phase-neutral); 50-600V (phase-phase)

Output maximum power: 800VA

Range output power

57.7V 800VA

100V 800VA

220V 800VA

380V 800VA

Resolution: 0.01%;

Stability: better than 0.05%/3 min (time base 5S);

Distortion factor: < 0.5% at linear load;

Frequency range: 45Hz~65Hz;

Power efficiency: more than 85%;

Ambient temperature: 10℃~50℃

Electronic overload and short-circuit protection.

Current amplifier:

Output current: range: 1mA~120A (option for 1mA~200A);

Output maximum power: 1500VA

Resolution: 0.01%;

Stability: better than 0.05%/3 min (time base 5S);

Distortion factor: < 0.5% at linear load;

Frequency range: 45Hz~65Hz;

Power efficiency: greater than 85%;

Ambient temperature: 10℃~50℃

Electronic overload protection and security for open current circuit

Phase Angle: 0°~360° , resolution of phase angle setting: 0.1°;

Output frequency range: 45Hz~65Hz; resolution: 0.01Hz

Harmonic wave output: 2-21 sub-harmonic wave contents≤40%

3, 5, 7 sub-harmonic wave coupling, total content≤40%

Phase angle control (odd sub-harmonic wave)

Wave group control (sub-harmonic wave)

Output stability of power: <0.05% (180S)

Numbers of calibrated energy meter: 16 (6/8/12/16/20/24/32/40 on requested)

Input power: 3×220V/380V (Y)15%, 50/60Hz; Max. Power consumption: 6000VA

Dimension:

Type of bench

Meters

Number

Number of row

Size

Integration

6

8

12

16

20

1

1

1

1

1

Single

Single

Double

Double

Double

2000×750×1650 mm

2400×750×1650 mm

2000×750×1920 mm

2400×750×1650 mm

2400×750×1650 mm

Fission

6

8

12

16

20

24

32

40

1

1

1

1

1

2

2

2

Single

Single

Double

Double

Double

Double

Double

Double

2000×600×1650 mm

2400×600×1650 mm

2000×600×1920 mm

2400×600×1920 mm

2400×600×1920 mm

2000×600×1920 mm

2400×600×1920 mm

2400×600×1920 mm

Console: 600×800×1920 mm

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628