1 / 1
Brand Name : | SEHM |
---|
Product description
Name | Unit | Parameter | Remark | |
Rated capacity | t | 5 |
| |
Max load capacity | t | 7 |
| |
Rated power | KW | 3000 |
| |
Working frequency | Hz | 500 |
| |
Melting rate | t/h | 3.5-4 | 1600°C,Rate of return scrap steel≥98%,Thermal, continuous, | |
Power consumption | kw.h/t | 550-630 | 1600°C,Rate of return scrap steel≥98%,Thermal, continuous, | |
Inductor inner diameter | mm | Φ1160 |
| |
Hight of inductor | mm | 1880 |
| |
Rated temperature of the melting steel | °C | 1600 |
| |
Incoming voltage of MF cabinet | v | 1000 |
| |
Electric rectificate mode |
| 12 Pulse |
| |
Voltage of inductor | V | 3300 | Double voltage | |
Cooling water of the furnace | Pressure of incoming water | Mpa | 0.25~0.3 |
|
Temperature of incoming water | °C | 5~35 |
| |
Temperature of the outlet water | °C | ≤55 |
| |
Flow rate ( furnace body ) | t/h | 120 | Single furnace 60 t/h | |
Flow rate (power source) | t/h | 50 |
| |
Water temperature rise of power source | °C | 10 |
| |
Cooling water pressure for power source | Mpa | 0.1~0.2 |
| |
Hydrauic system | Working pressure | Mpa | 12 |
|
Flow rate | L/min | 60 |
| |
Hydraulic medium |
| Antiwear hydraulic oil | Summer:N68 Winter:N46 | |
Diameter of the hydraulic cylinder | mm | Φ160 |
| |
Transformer | Capacity of the transformer | KVA | 4000 |
|
Incoming voltage | KV | 35 |
| |
Secondary voltage | V | 1000 |
| |
Connection |
| Dd0yn11 |
| |
Impedance voltage |
| 8~9% |
| |
Phase |
| 3-phase input, 6-phase output |
|