Digital Multimeter with Analog Bargraph, Available in Auto-ranging Function
Digital Multimeter with Analog Bargraph, Available in Auto-ranging Function
Digital Multimeter with Analog Bargraph, Available in Auto-ranging Function

1 / 1

Digital Multimeter with Analog Bargraph, Available in Auto-ranging Function

Get Latest Price
Send Inquiry
Model No. : DT-2006
Brand Name :
10yrs

Shenzhen, Guangdong, China

Visit The Store

Product description

  • Features:
    • 6000 digital display counts with backlit
    • Data hold, max/min recording mode
    • Full overload protection on all ranges
    • Auto-ranging function
    • Analog bargraph/61 segments
    • BAT symbolic sign
  • Specifications:
    • DC voltage measurement:
      • Range: 600.00mV, 6.000V, 60.00V, 600.0V, 1000V
      • Basic accuracy: ± (0.5%+2d)
      • Resolution: 0.1mV
    • AC voltage measurement:
      • Range: 6.000V, 60.00V, 600.0V, 700V
      • Basic accuracy: ± (1.0%+3d)
      • Resolution: 1mV
    • DC current measurement:
      • Range: 600.0uA, 6000uA, 60.00mA, 600.0mA, 6A, 20A
      • Basic accuracy: ± (1.5%+3d)
      • Resolution: 0.1uA
    • AC current measurement:
      • Range: 600.0uA, 6000uA, 60.00mA, 600.0mA, 6A, 20A
      • Basic accuracy: ± (2.0%+3d)
      • Resolution: 0.1uA
    • Resistance measurement:
      • Range: 600.0&, 6.000k&, 60.00k&, 600.0k&,6.000M&, 60.00M&, 600.00M&, 6000M&
      • Basic accuracy: ± (1.2%+2d)
      • Resolution: 0.1&
    • Capacitance measurement:
      • Range: 40.00nF, 400.0nF, 4.000uF, 40.00uF, 400.00uF,4000uF
      • Basic accuracy: ± (4.0%+3d)
      • Resolution: 10pF
    • Frequency measurement:
      • Range: 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1000kHz, 10MHz,20MHz
      • Basic accuracy: ± (1.5%+5d)
      • Resolution: 0.001Hz
    • Temperature measurement:
      • Range: -20 to +760/-4 to +1400
      • Basic accuracy: +3% of rdg +7dgts
      • Resolution: 1 /
    • Diode check and continuity test:
      • Diode test: test current of 1mA maximum, open circuit voltage2.8V DC typical
      • Continuity check: audible signal will sound if the resistanceis less than 100& (approx.), test current <1.5mA
  • 6000 digital display counts with backlit
  • Data hold, max/min recording mode
  • Full overload protection on all ranges
  • Auto-ranging function
  • Analog bargraph/61 segments
  • BAT symbolic sign
  • DC voltage measurement:
    • Range: 600.00mV, 6.000V, 60.00V, 600.0V, 1000V
    • Basic accuracy: ± (0.5%+2d)
    • Resolution: 0.1mV
  • AC voltage measurement:
    • Range: 6.000V, 60.00V, 600.0V, 700V
    • Basic accuracy: ± (1.0%+3d)
    • Resolution: 1mV
  • DC current measurement:
    • Range: 600.0uA, 6000uA, 60.00mA, 600.0mA, 6A, 20A
    • Basic accuracy: ± (1.5%+3d)
    • Resolution: 0.1uA
  • AC current measurement:
    • Range: 600.0uA, 6000uA, 60.00mA, 600.0mA, 6A, 20A
    • Basic accuracy: ± (2.0%+3d)
    • Resolution: 0.1uA
  • Resistance measurement:
    • Range: 600.0&, 6.000k&, 60.00k&, 600.0k&,6.000M&, 60.00M&, 600.00M&, 6000M&
    • Basic accuracy: ± (1.2%+2d)
    • Resolution: 0.1&
  • Capacitance measurement:
    • Range: 40.00nF, 400.0nF, 4.000uF, 40.00uF, 400.00uF,4000uF
    • Basic accuracy: ± (4.0%+3d)
    • Resolution: 10pF
  • Frequency measurement:
    • Range: 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1000kHz, 10MHz,20MHz
    • Basic accuracy: ± (1.5%+5d)
    • Resolution: 0.001Hz
  • Temperature measurement:
    • Range: -20 to +760/-4 to +1400
    • Basic accuracy: +3% of rdg +7dgts
    • Resolution: 1 /
  • Diode check and continuity test:
    • Diode test: test current of 1mA maximum, open circuit voltage2.8V DC typical
    • Continuity check: audible signal will sound if the resistanceis less than 100& (approx.), test current <1.5mA
  • Range: 600.00mV, 6.000V, 60.00V, 600.0V, 1000V
  • Basic accuracy: ± (0.5%+2d)
  • Resolution: 0.1mV
  • Range: 6.000V, 60.00V, 600.0V, 700V
  • Basic accuracy: ± (1.0%+3d)
  • Resolution: 1mV
  • Range: 600.0uA, 6000uA, 60.00mA, 600.0mA, 6A, 20A
  • Basic accuracy: ± (1.5%+3d)
  • Resolution: 0.1uA
  • Range: 600.0uA, 6000uA, 60.00mA, 600.0mA, 6A, 20A
  • Basic accuracy: ± (2.0%+3d)
  • Resolution: 0.1uA
  • Range: 600.0&, 6.000k&, 60.00k&, 600.0k&,6.000M&, 60.00M&, 600.00M&, 6000M&
  • Basic accuracy: ± (1.2%+2d)
  • Resolution: 0.1&
  • Range: 40.00nF, 400.0nF, 4.000uF, 40.00uF, 400.00uF,4000uF
  • Basic accuracy: ± (4.0%+3d)
  • Resolution: 10pF
  • Range: 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1000kHz, 10MHz,20MHz
  • Basic accuracy: ± (1.5%+5d)
  • Resolution: 0.001Hz
  • Range: -20 to +760/-4 to +1400
  • Basic accuracy: +3% of rdg +7dgts
  • Resolution: 1 /
  • Diode test: test current of 1mA maximum, open circuit voltage2.8V DC typical
  • Continuity check: audible signal will sound if the resistanceis less than 100& (approx.), test current <1.5mA
  • Send Inquiry

    Product Alert

    Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.