Concrete rebar detector/ location scanning equipment R51
Concrete rebar detector/ location scanning equipment R51
Concrete rebar detector/ location scanning equipment R51

1 / 1

Concrete rebar detector/ location scanning equipment R51

Get Latest Price
Send Inquiry
Model No. : R51
Brand Name : Galaxy

Product description

Specifications Concrete rebar detector/ location scanning equipment R51

Concrete rebar detector/ location scanning equipment R51   Application: R51 steel-bar Location tester used to test steel-bar diameter, Distribution, backing thickness in concrete.   Specification: <Technical specification for test of reinforcing Steel bar in concrete> JGJ/T152-2008   Performance: 1. Longer service life of the connector clip. The instrument has long service life because of using lemo connector clip which    comes form Switzerland  and used for aircraft industry.
2. Good quality of signal cable. The signal cable has long service life because of its flexible and substance .
3. High precision and stability. The instrument can locate the steel-bar accurately and quickly.
4. Longer service life of the sensor. Improve the service life by paste abrasion resistance allowance on the bottom of the    sensor.
5. Single sensor test. Do notneed to change the sensor during the test. it can assure the precision of test data and the test    depth that switching between the low and high test range.
6. Real-time Display  test information. Interpret and display the test data Intelligently to avoid man-made errors.
7. Powerful data process and analysis software in windows. Test data can be export to word or excel easily.   Technical Data  

Applicable steel-bar diameter

6mm~50mm

Tested range of concrete backing thickness

Low range: 6mm~90mm; High range:7mm~190mm.

Maximum permissible errors of concrete cover thickness

 

Low range 

High range

±1

6~59

7~79

±2

60~69

80~119

±4

70~90

120~190

Tested range of steel-bar diameter

6mm~50mm

Permissible error of steel-bar diameter test

±1 grade

Applicable environmental

temperature-10℃~+40℃; Dampness<90%RH

EMI: no Strong electromagnetic field

Power supply

6 dry cells, work more than 30 hours

     Configuration             
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.