China most Professional Patient Monitor Manufacturer, cheap patient monitor for sale Overview Patient monitor is widely used in opration, emergency treatments, ICU, CCU and other clinical monitoring.using Import original 12.1 or 15 inch true color TFT LCD makes the operation interface clearer.the unit with small size, light weight is suitable for bedside, outside and ambulance ICU. It has the functions of ECG testing, SPO2 testing, NIBP testing, RESP testing, TEMP testing and PR testing. Accessories list A mainframe 5 leads ecg cable (Breathing probe and temperature probe included ) A Blood pressure cuff for adult A Blood pressure extension tube A blood oxygen probe for adult Power adapter A bag of ECG electrodes (20 pieces) A Manual 3 certificates for the machine
Description 12.1 or 15 inch true color TFT LCD displayer Standard Configuration: ECG device, SPO2 device, NIBP device, RESP device, TEMP device, PR device Optional Configuration 2-IBP CO2 7-lead/12-Lead ECG on-one-screen display, ECG waveform cascading display Drug concentration calculation function Optional Colors for Waveform and data 72 hours (480H max) trend data storage and 40 seconds waveform hologram playback 72 hours ECG waveform storage and playback Digital SPO2 technology, anti-motion interference, strong anti Weak filling Condition capability Network Functions : connection with the central station, other bed observation, software update; wireless or wire connection Large character interface In-built rechargeable maintenance-free battery In-built printer(optional) Specification and Technical parameters ECG Lead Mode: 3 or 5 Leads optional Lead Selection: I,II,III / I,II,III,avR,avL,avF,V Gain: X1/4, X1/2, X2, X4, HR range: 15~300bpm (Adult), 15~350bpm (Neonatal) Heart rate accuracy: ±1% Resolution: 1 BPM Protection: Quarantine sustain 4000V,50/60Hz Anti-defibrillation protection: Anti-interference from high frequency electric knife leakage current: <10μA Arrhythmia analysis ,review: yes NIBP Method: Automatic Oscillometric Measurement parameters: systolic, mean, diastolic Measurement mode: Manual, automatic and STAT Units of measurement: mmHg/Kpa Accuracy: ±3mmHg Resolution: 1 mmHg Automatic measuring time: Settable Over-voltage protection: yes SpO2 Display: Waveform and digits Measuring Range: 0~100% Resolution: 1% Accuracy: ±2%(70~100%) ±3%(0%~69%) Pulse Rate Pulse Rate range: 15~300bpm Resolution: 1bpm Accuracy: ±2bpm TEMPERATURE Temperature range:0~50℃ Display: T1, T2 Resolution: 0.1℃ Accuracy: ±0.1℃ RESPIRATION Measuring range: 7~120 BRPM (adult), 7~150 BRPM (children,neonatal) Resolution: 1 BRPM Accuracy: ±2 BRPM Measuring method: RA-LL Impedance Asphyxia monitor alarm: yes In-Built Printer (optional) Waveform description: Single lead, three lead paper speed: 12.5mm/s,25mm/s,50mm/s Record: Manual, alarm , time setting EtCO2 Measurement Range: 0~13% (0~100mmHg) Unit: %, mmHg, kPa Respiration Rate Range: 3~150bpm Respiration Rate Measure Accuracy: 1% ±1BPM CO2 Measure Accuracy: < 5.0% CO2 : ± 2 mmHg; > 5.0% CO2 : < 10% of value Flow Control : 50~250ml/min Adjustable Power supply AC: 100~250(V), 50/60(Hz) DC: 4 Ah 12V rechargeable sealed battery Working Environment Temperature : 0~40 (℃) Humidity: ≤85% Altitude: -500 to 4,600m (-1,600 to 15,000ft) Transport and Storage Temperature: -20~60 (℃) Humidity : ≤93% Altitude: -500 to 13,100m (-1,600 to 43,000ft) Net Weight: 4.5 kg Gross Weight: 6.2 kg Dimension: 440mm*340mm*450mm Standard Configuration: ECG SPO2 NIBP RESP TEMP PR/font Optional Configuration: 2-IBP, ETCO2. Features The operation interface is direct-viewing ,easy for operation Built-in high capacity rechargeable battery , convenient to transfer patient long time waveform and recording data playback and browse function Automatic acousto-optic alarm Resist defibrillation effect and interference of high frequency electrotome Portable design, stylish outlook and easy handle(windows interface similar) Complete built-in module design ensures stable and reliable performance(IBP-CO2 optional)