1 / 1
Model No. : | SL-120-12 |
---|
Product description
Model | SL-120-5 | SL-120-12 | S-120-18 | SL-120-24 | SL-120-36 | SL-120-48 | SL-120-60 | |
Output | DC voltage | 5V | 12V | 18V | 24V | 36V | 48V | 60V |
Rated power | 24A | 10A | 6.7A | 5A | 3.4A | 2.5A | 2A | |
Current range | 0-24A | 0-10A | 0--6.7A | 0-5A | 0--3.4A | 0--2.5A | 0--2A | |
Power | 120W | 120W | 120W | 120W | 120W | 120W | 120W | |
Ripple & Noise (max.) | 95mVp-p | 120mVp-p | 130mvp-p | 140mVp-p | 140mVp-p | 150mVp-p | 160mVp-p | |
Voltage ADJ.range V | 4.2--6.4 | 9.5--14.6 | 15.8--21 | 21--26.5 | 30.5--40 | 42.5--55 | 55--64 | |
Setup, Rise Time, Hold up time (Typ.) | 200ms,40ms,30ms/230VAC. | |||||||
Input | Voltage range | 95VAC--265VAC(By switch) 47~63Hz, upper bound 280VAC | ||||||
AC curren | 4A/115V 2A/230VAC | |||||||
Efficiency | 76% | 78% | 80% | 80% | 82% | 83% | 85% | |
Inrush current | CCA,coolstartcurrent 15A/230VAC 30A/115VAC | |||||||
Leakage current | <3mA/230VAC -115VAC | |||||||
Protection | Overload | Rated output power 115%~135% | ||||||
Shut down o/p voltage, re-power on to recover | ||||||||
Over voltage | 135% | 120% | 120% | 115% | 120% | 110% | 110% | |
Shut down o/p voltage, re-power on to recover | ||||||||
Over temperature | Shut down o/p voltage, recovers automatically after temperature back to normal | |||||||
Environment | Working temperature, humidity | -15degrees~+65degrees;20%~90%RH | ||||||
Storage temperature, humidity | -20degrees~+85degrees;10%~95%RH non=condensing | |||||||
Safety | Withstand voltage | 0.5KVAC :1.5KVAC output:1.5KVAC | ||||||
Insulation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||||
Compliance Standard | Safety standard | Compliance UL1012 | ||||||
EMC Standard | Compliance EN55022,CLASSA | |||||||
Remarks | 1. All parameters are measured at 230VAC input, rated load and under 25 degrees, unless specified. | |||||||
2. Ripple and noise voltage is at 20MHz of bandwidth 12 inches twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. . | ||||||||
3. Tolerance: includes set up tolerance, line regulation and load regulation . |