1 / 1
Model No. : | NCS-PTII105 |
---|---|
Brand Name : | Microcyber |
Product description
Measure object | Liquid, gas, stream | |
Power | 9~32V DC(FF,PA) 9~32V dc (FF, PA Explosion-proof instrument) 11.9~42 V DC (HART) 11.9~30 V DC (HART Explosion-proof instrument) | |
Output | Analog: 2 wire 4~20mA Digital: HART, FF and PA signal | |
Load resistant | 0~1500ohm (common) 250~550ohm (with HART) | |
Insulation | Input and output insulating voltage: 500Vrms (707VDC) | |
Display | Optional 6 bits digital number or 5 bits characters LCD display | |
Temperature scale | Work temperature: -40 - 85°C (No display) -30 - 70°C (display) -30 - 60°C (Explosion-proof) Store temperature: -40 - 100°C (No display) -40 - 85°C (display) | |
Allowed media temperature measured | -40 °C - 110 °C (Type name include ‘IC’) -40 °C - 149 °C (silicone oil) -40 °C - 204 °C (sylthlem800) -18 °C - 204 °C (inert liquid) -40 °C - 104 °C (others) | |
Humidity scale | 5%-100%RH | |
Start time | ≤ 5 seconds | |
Refresh time | 0.2 seconds | |
Dump adjusting | Time constant 0-15 seconds | |
Change of cavity | < 0.16 cm3 | |
Static pressure limit | SR | Range 2: 1000psi (6.89MPa) |
SD | Range 3-8: 2000psi (13.8MPa) | |
SG | Range 3-8: 2000psi (13.8MPa) Range 9: 4500psi (31.0MPa) Range 0: 7500psi (51.7MPa) | |
SA | Range 4: 58psi (400kPa) Range 5: 218psi (1500kPa) Range 6: 435psi (3000kPa) | |
SH | Range 4-7: 4500psi (31.0MPa) |
Precision | For range 2 ±0.1% of Span is for 0.5 URL≤Span ≤ URL; ±[0.05+0.025 ×(URL / Span)]% of Span is for Span<0.5 URL. For other ranges ±0.075% of Span is for 0.1 URL≤Span ≤ URL; ±[0.025+0.005 ×(URL / Span)]% of Span is for Span<0.1 URL |
Temperature effect | Total effects per 28°C(50°F)change: For range 2 ±[0.05% URL +0.25% Span] For other ranges Span≥0.1 URL: ±[0.019% URL +0.125% Span] Span<0.1 URL: ±[0.025% URL +0.125% Span] |
Long time stability | In 12 months, ±0.1% of maximum range |
Static pressure effect | For range 2 ±1% / 13.8MPa For range 3 ±0.5% / 13.8Mpa For other ranges ±0.25%/13.8MPa |
Location installed effect | The maximum of the zero point movement is 0.24kPa |
Power effect | < 0.005%/V of range calibrated |
Explosion-proof | intrinsically safety Ex ia II C T4 |
Explosion-proof level | IP65 or IP67 |
Vibration effect | Meet GB/T 2423-1995 |
Electromagnetic compatibility | Meet GB/T 17626-1998 (IEC 61326-1:1997) |
Electrical connection | 1/2-14NPT thread in. |
Process connection | 1/4-18 NPT thread in. |
Drawing pressure connector | Range 2~5, distance of center is 2.122 inch (53.9mm) Range 6, distance of center is 2.176 inch (55.3mm) Range 7, distance of center is 2.197 inch (55.8mm) Range 8, distance of center is 2.236 inch (56.8mm) Range 9, distance of center is 2.260 inch (57.4mm) Range 0, distance of center is 2.291 inch (58.2mm) |
Structural materials | Isolated Membrane and exhaust/outlet valve: 316 stainless steel Flange and connector: 316 stainless steel O-ring: fluororubber Filled liquid: silicon oil or fluorocarbon oil Bolt: zinc plating carbon steel (the material above should be selected at order, if has other requirement, please report in advance) Housing: low copper of albronze Coating: dion epoxy resin |
Height | Display type: 3.5kg No display type: 3.3kg |
Send your inquiry to this supplier