Model No. : | Inverter |
---|---|
Brand Name : | ACI |
Product description
Project | Standard specification | |
Input | Rated voltage/ Frequency | Single-phase 220V, three-phase 220V, three-phase 380v / 50Hz/60Hz |
Change allowable value | Voltage: -20% ~ +20%, Voltage unbalance ratio:<3% ,Frequency:±10% | |
Output | Rated voltage | 220V/380V |
Frequency range | 0Hz ~ 500hz | |
Frequency resolution | 0.01Hz | |
Main control function | Overload capacity | 150% rated current for 1 minute, light load 120% rated current for 1 minute heavy load 120% rated current for 1 minute |
Modulating method | Optimize space voltage vector SVPWM modulation | |
Control mode | Space voltage vector SVPWM control (with characteristic of optimum low-frequency death area compensation) | |
Frequency accuracy | Data setting: highest frequency ×±0.01%, Analog setting: highest frequency ×±0.2% | |
Frequency resolution | Data setting: 0.01Hz, Analog setting: highest frequency ×0.1% | |
Start frequency | 0.4Hz~20.00Hz | |
Torque boost | Auto torque boost, manul toque boost 0.1%~ 30.0% | |
V/F curve | Five modes: constant torque V/F curve, 1V/F curve set by user, 3 drop torque characteristic curves(2.0 power, 1.7 power and 1.2 power) | |
Acceleration/ deceleration curve | Two mode: linear acceleration/deceleration, S curve acceleration/ deceleration, seven kinds of acceleration/ deceleration time, time unit is selective(minute/second), max is 6000 minutes | |
DC braking | DC braking start frequency: 0~15.00Hz Braking time: 0~60.0 seconds braking current: 0~80% | |
Energy consumption braking | Built-in energy comsuption braking unit, may external connect braking resistor | |
Inching | Inching frequency range: 0.1Hz~50Hz, inching acceleration/deceleration time 0.1~60.0 seconds | |
Built-in PI | To form closed-loop control system conveniently | |
Multistage speed running | To realize Multistage speed running via built-in PLC or control terminal | |
Wobble frequency | Can realize pre-set frequency function, centre frequency function adjustable | |
Automatic voltage regulation(AVR) | When the voltage of power network changes, it can keep output voltage constant | |
Automatic energy-saving running | Optimize V/F curve automatically according to load condition to realize energy saving when running | |
Automatic current limiting | Limit the current automatically during running, thus to avoid freqent over-current trip | |
Fixed-length control | Inverter stops after arriving fixed-length | |
Communication function | With RS485 standard communication interface, support ASCII and RTU format MODBUS communiction protocol. With the function of multi-machine interaction between master and slave computer | |
Running function | Running command method | Operation panel given, control terminal given, serial port given, three-method switch available |
Frequency setting method | Keyboard analog potentiometer preset, keys preset, function code data preset, serial port preset, terminal UP/DOWN preset, analog voltage preset, analog current preset, pulse preset,combination preset, various methods can be given switch at any time | |
Switch input method | Forward/reverse rotation command, 8 paths programmable switch value input, may set 35 function, respectively | |
Analog input method | 2 way analog signal input, 4~20mA, 0~10V selective | |
Analog output method | Analog signal input, 4~20mA, 0~10V selective, can realize physical volunm output such as setting frequency, output frequency | |
Switch, pulse output method | 1 way programmzble open collector output, 1 way relay output signal, 1 way 0~20KHz pulse output signal, realize all kinds of physical quantity output | |
Operation panel | LED digital display | May display set frequency-set, output voltage, input current parameters, etc. |
External meter display | Display physical quantity such as output frequency, output current, output voltage | |
Keys lock | Realize all keys lock | |
Parameter copy | May realize function code parameter copy between inverter via remote keyboad operation | |
Environment | Application places | Indoor, no direct exposure to sunlight and no dust, no corrosive gas, no oil mist, no water drop, etc. |
Altitude | Below 1000m (must derate if above 1000m) | |
Ambient temperature | -10℃~+40℃ | |
Humidity | 90% RH or less, non-comdensing | |
Vibration | 5.9m/s² or less(0.6G) | |
Storage temperature | -20℃~+60℃ | |
Protection grade | IP20 | |
Cooling method | Forced air-cooling | |
Mounting mode | Wall-mounted type, installation inside cabinet | |
Protection function | Over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection | |
Option | Braking unit, remote operation panel, remote cable, keyboard installation, etc |