building material,glass wool building material,roofing panels building material
1. Main specification range A.Glass wool felt/blanket/batt/roll Density:10-48kg/m3
Length:5m-30m
Width:1200mm,600mm
Thickness:25mm-185mm B.Glass Wool Board Description Density: 24-96kg/m3 Length: 1200-2400mm Width:600-1200mm Thickness: 20-100mm C.Glass wool pipe Density :48-80kg/m3 Thickness: 25-100mm With/wihtout Alu. foil The characteristics of glass wool A. Low thermal conductivity, insulation performance is good. B. Sound absorption performance is good. C. Fireproof, non-toxic, safety in use D. ante-corrosion, moisture resistant, anti-aging E. good elasticity,doesn‘t deform 2. Technical Parameter Datal parameter Data echnical parameter Data
Number | Item | Unit | National Standard | Company Product | Remark |
1 | Density | kg/m3 | | 10-48 | GB483.3-85 |
2 | Avearage Fiber diameter | μm | ≤8.0 | 5.5 | GB5480.4-85 |
3 | Hygroscopicity | % | ≥98 | 98.2 | GB10299-88 |
4 | Thermal Conductivity | w/m.k | ≤0.042 | 0.033 | GB10294-88 |
5 | Noncombustibility | 0 | Noncombustible | Noncombustible (A) | GB5464-85 |
6 | Sound Absorption Coefficient | 0 | 0 | 1.03 product reverberation method 24kg/m3 2000HZ | GBJ47-83 |
7 | Highest usage Temperature | °C | ≤480 | 480 | GB11835-89 |
3. Usage A. Heat insulation for steel structure building
B. Heat insulation for wall and roof of house to save energy
C. Sound absorption and noise reduction for recreation places (theatre, movie theater, KTV, etc.) and household appliances (computer, air pressure machine, etc.), air conditioner pipe, refrigeration equipment D. Heat insulation for refrigerating warehouses
4.Service 24 hours prompt reply by email or telephone or messenger. Standard size have stock, immediately delivery once your purchase. 10 days delivery containers for out of stock glass wool No quantity limit, from 1 rolls to 100 containers, at your choose and demand!