Specifications 1. medical surgical equipment for hospital

2.7 monopolar modes & 2 bipolar modes

3. can perform endoscopic surgery

4. CE ISO

medical surgical equipment for hospital BC-50F High Frequency Electrosurgical Unit  Electrosurgical/HF surgical/HF Electric Specifications   1. Classification: Class I Type CF 2. Main Frequency: 625kHz±5% Modulate Frequency: 25kHz±5% 3. Working Mode: Intermittent and continuous working, 10s/30s 4. Output power and peak voltage:  

 

Spec. Mode

Output Power

Power Range

Resistance

Monopolar Pure cutting

2~350W

500Ω

Monopolar Blend 1

2~250W

500Ω

Monopolar Blend 2

2~200W

500Ω

Monopolar Blend 3

2~200W

500Ω

Monopolar Contact Coagulation

2~200W

500Ω

Monopolar Standard Coagulation

2~200W

500Ω

Monopolar Spray Coagulation

1~70W

150Ω

Bipolar Standard Coagulation

1~70W

150Ω

Bipolar Accurate Coagulation

1~70W

150Ω

5. Automatic Storage: The working mode and output power set during operation can be stored in the unit for 100 years. 6. High Frequency Leakage Current   The neutral electrode is isolated from the earth during the high frequency operation, the High Frequency Leakage Current <150mA. 7. Output Channels: Monopolar: 1 channel, Bipolar: 1 channel.   8. Output Setting and Indicating: The output is set by key pressing in different area according to different working mode, it is displayed digitally. 9. Output Indicating Visual Indicator: Monopolar Cutting - Yellow / Coag - Blue / Bipo - Blue Audio Indicator: When the power is output, there is an audio indicator, the volume can be adjusted. 10. Error Indicating Visual Indicator: The red indicator indicating the error and danger detected by self-detecting or monitoring (ALARM); Audio Indicator: When alarming, there is an pulse audio indicating, this volume cannot be adjusted. 11. Output Control  monopolar: Hand Control, Foot Control; Bipolar: Foot Control, Automatic Control.   12. Main Supply: AC220V±10% 50Hz±2% 13. Dimension: 380mm×450mm×170mm 14. Net Weight: 7.5 kg 15. Operation Condition: Environment Temperature: +5°C~+40°C Relative Humidity: ≤85% 16. Transport and Storage Condition: Environment Temperature: -40°C~+50°C Relative Humidity: ≤90%   This intelligent product is designed for big-middle hospital.   The system has NE CONTINUITY MONITOR, intended for connection to an NE (single plates),providing an alarm in the event of electrical discontinuity in the NE cable or its connections. as well as Neutral electrode contact quality monitor (CQM), intended for connection to a MONITORING NE (split plates) providing an alarm in the event that NE contact with the PATIENT becomes insufficient.   This system can be used together with the endoscope, to perform endoscopic surgery. It is intended for general surgery, orthopedic surgery, chest surgery, cardiovascular surgery, gynecology, urology, tumor, gastroenterology, neurology and so on.  

surgical mode

Cutting

Coagulation

Bipolar

Pure

Blend 1

Blend 2

Blend 3

Coag 1

Coag 2

Coag 3

Bipo 1

Bipo 2

Rated Power

350W

250W

200W

200W

200W

200W

100W

70W

70W

Rated Load

500Ω

500Ω

500Ω

500Ω

500Ω

500Ω

500Ω

150Ω

150Ω

   