ATNL-900 Infusion Pump

Specifications

Large LCD display, with backlight, suitable for working in various ambient light conditions.
Disposable IV set of any brand is suitable for this pump
Three working modes: Rate/Volume/Time mode
Purge, KVO function
Heating function is optional, suitable for infusing in winter or there is requirement for the medication temperature.
Remote Controller makes operating more convenient.
Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission.
Simple and convenient in operating, intuitive presence of working status.
Audible and Visible alarms
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Size: 188 mm(L)*198 mm(W)*228 mm(H)
Net Weight: 2.2kg

Technical Specifications

Pump TypeDrip type infusion pump
Pumping WayPeristalic fingers
Adjustable Drop Rate Range1~400 drops/min (step: 1 drop/min)
Adjustable Volume Rate Range1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; Greater than 99.9 ml/h, step: 1 ml/h)
Flow PrecisionWithin 3% more or less(using the IV set appointed by the manufacturer or calibrated high quality IV set)
Mechanical precisionwithin 2% more or less
Purge Rate800 ml/h
KVO Rate1 ml/h (1~300 ml/h)
3 ml/h (greater than 300 ml/h)
Infusion Volume Range1 ml~9999.9 ml (step: 0.1 ml)
Maximum Accumulated Volume9999.9 ml (step: 0.1 ml)
Time Range1 min~9999 min (step: 1 min)
Occlusion Alarm ThresholdHigh: 800 mmHg+-200 mmHg (106.7kPa+-26.7kPa)
Medium: 500 mmHg+-100 mmHg (66.7kPa+-13.3kPa)
Low: 300 mmHg+-100 mmHg (40.7kPa+-13.3kPa)
AlarmInfusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Air Bubble Detector Methodultrasonic wave, sensitivity: More than or equal
25 μ L
FuseF1AL/250V ("F" indicate fast, "L" indicate low breaking capacity), 2 pcs (installed inside pump).
Power SupplyAC 85~265V, 50/60Hz;
Internal Battery11.1V rechargeable li-ion battery. Capacity: More than or equal 2000mAh;
The pump can work more than 4 hours at the flow rate of 25 ml/h after charging for 8 hours (Medium rate specified by GB 9706.27-2005).
Powerless than or equal 40VA
Size188 mm(L)*198 mm(W)*228 mm(H)
Weight2.2KG
Environment RequirementsTransport
Ambient Temperature: -30° C~+55° C
Relative Humidity: 20%~95% (non-condensing)
Atmosphere Pressure: 70kPa~106kPa
Storage
Ambient Temperature: -30° C~+55° C
Relative Humidity: 20%~95%
Atmosphere Pressure: 70kPa~106kPa
Operation
Ambient Temperature: +5~+40° C
Relative Humidity: 20%~90%
Atmosphere Pressure: 86kPa~106kPas
Calibration functiondisposable IV set of any brand is suitable for this pump
Three working modesRate/Volume/Time mode
AlarmInfusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Infusion monitoring system (Optional),
The status of each pump is displayed in real time at the central station through wireless transmission.
4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions.
Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628