1 / 5
Model No. : | 1*6AWG+1*6AWG cable |
---|---|
Brand Name : | taifa |
Product description
ABC Duplex cable Shepherd 1*6AWG+1*6AWG
1.Properties
ABC cable is primarily used on lighting, outdoor lighting, and temporary service for construction.
To be used at voltages of 600V phase-to-phase or less,
and the conductor temperatures no exceeds 75 degrees for polyethylene(PE) insulated conductors or 90 degrees for corsslinked polyethylene(XLPE) insulated conductors.
2. Application of Service Drop Cables
2.1 DuplexService Drop
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower ATA conductor temperature of 750C maximum.
2.2 Triplex Service Drop
To supply power from the utility`s lines to the consumer`s weather head. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
2.3 Quadruplex Service Drop
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
3. Construction
Concentric stranded or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
4.ABC cable meets of exceeds the following specifications
Aluminum cable,1350-H19 for electrical purposes.
Aluminum conductors,concentric lay stranded.
Aluminum conductor,concentric lay stranded,coated steel reinforced(ACSR).
Concentric lay stranded,6201-T81 conductors.
Compressed round stranded aluminum conductors using single input conductor.
ABC cable meets or exceeds all appliable requirements of ANSI/ICEA S-76-474
2. Duplex Service Drop ACSR Neutral-Messenger Aluminum Conductor | ||||||||||||||
Items | Phase Conductor Size | Phase Conductor Stranding | Phase Conductor Insulation Thickness | Phase Conductor Insulation Thickness | Bare Neutral Messenger Size | Bare Neutral Strand | Bare Neutral Messenger Breaking Strength | Bare Neutral Messenger Breaking Strength | Weight Per 1000ft-XLP | Weight Per 1000ft-Poly | Weight Per KM -XLPE | Weight Per KM- PVC | Rating-XLP | Rating-Poly |
AWG | mls | mm | AWG | Lbs | N | Lbs | Lbs | Kg/Km | Kg/Km | |||||
Setter | 6 | Solid | 45 | 1.143 | 6 | 6/1 | 1190 | 5289.91 | 75 | 73.2 | 111.60 | 108.92 | 70 Amps | 70 Amps |
Shepherd | 6 | 7/w | 45 | 1.143 | 6 | 6/1 | 1190 | 5289.91 | 78.3 | 74.6 | 116.51 | 111.00 | 70 Amps | 70 Amps |
Eskimo | 4 | Solid | 45 | 1.143 | 4 | 6/1 | 1860 | 8268.26 | 113.7 | 111.6 | 169.19 | 166.06 | 90 Amps | 90 Amps |
Terrier | 4 | 7/w | 45 | 1.143 | 4 | 6/1 | 1860 | 8268.26 | 118.7 | 113.6 | 176.63 | 169.04 | 90 Amps | 90 Amps |
Chow | 2 | 7/w | 45 | 1.143 | 2 | 6/1 | 2850 | 12669.11 | 181.7 | 174.7 | 270.37 | 259.95 | 120 Amps | 120 Amps |
Bull | 1/0 | 19/w | 60 | 1.524 | 1/0 | 6/1 | 4380 | 19470.41 | 288.7 |
.