6v/12v 3.2ah rechargeable lead acid battery grid battery power storage
6v/12v 3.2ah rechargeable lead acid battery grid battery power storage
6v/12v 3.2ah rechargeable lead acid battery grid battery power storage

1 / 1

6v/12v 3.2ah rechargeable lead acid battery grid battery power storage

Get Latest Price
Send Inquiry
Model No. : NP3.2-12
Brand Name : YUASA

Product description

Specifications 6v/12v 3.2ah rechargeable lead acid battery

1)professional manufacturer

2)fast deliver

3)Deep cycle

4)OEM

6v/12v 3.2ah rechargeable lead acid battery grid battery power storage             RECHARGEABLE BATTERY   1. PRODUCT INFORMATION SPECIFICATION  

Model

NP3.2-12

Voltage(V)

12

Capacity(10Hr)(AH)

3.2

Dimensions
(L x W x H/T.H)(mm)

134*67*60/64

Weight(KG)

1.20

Teiminal

Lead

  CONSTRUCTION    

A

Positive Plate

Lead

B

Negative Plate

Lead

C

Container

ABS

D

Cover

ABS

E

Safety Valve

Si-Rubber

F

Terminal

Lead

G

Separator

GFM

H

Electrolyte

Lead Acid

    deep cycle battery 12v3.2ah, UPS battery, solar battery : Life time, Deep cycle times....etc           2. FEATURES Features Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination. Multipurpose: Float or Cyclic use. Usable in any orientation (except continuous inverted). Superior energy density. Lead calcium grids for extended life. Manufactured world wide. Application specific designs.   Technical Features   Sealed Construction  
Yuasa's unique construction and sealing technique
ensures no electrolyte leakage from case or terminals.  
Electrolyte Suspension System
All NP batteries utilize Yuasa's unique electrolyte
suspension system incorporating a microfine glass mat to
retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and
there is no free electrolyte to escape from the cells. No
gels or other contaminants are added.   Control of Gas Generation  
The design of Yuasa's NP batteries incorporates the very
latest oxygen recombination technology to effectively
control the generation of gas during normal use.  
Low Maintenance Operation  
Due to the perfectly sealed construction and the
recombination of gasses within the cell, the battery is
almost maintenance free.  
Terminals
NP batteries are manufactured using a range of terminals
which vary in size and type. Please refer to details as
shown.     3. Terminal   Operation in any Orientation  
The combination of sealed construction and Yuasa's
unique electrolyte suspension system allows operation
in any orientation, with no loss of performance or fear of
electrolyte leakage. (Excluding continuous use inverted)   Valve Regulated Design  
The batteries are equipped with a simple, safe low
pressure venting system which releases excess gas
and automatically reseals should there be a build up of
gas within the battery due to severe overcharge. Note.
On no account should the battery be charged in a
sealed container.  
Lead Calcium Grids  
The heavy duty lead calcium alloy grids provide an
extra margin of performance and life in both cyclic and
float applications and give unparalleled recovery from
deep discharge.   Long Cycle Service Life  
Depending upon the average depth of discharge, over
a thousand discharge/charge cycles can be expected.  
Float Service Life  
The expected service life is five years in float standby
applications.  
Separators  
The use of the special separator material provides
a very efficient insulation between plates preventing
inter-plate short circuits and prohibiting the shedding
of active materials.  
Long shelf Life
The extremely low self discharge rate allows the battery
to be stored for extended periods up to one year at
normal ambient temperatures with no permanent loss
of capacity.       4. Operating Temperature Range   The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location: °C Charge:        -15 °C to 50 °C   Discharge       -20 °C to 60  °C   Storage          -20°C to 50 °C (fully charged battery) Applications  
Yuasa NP batteries, having excellent deep discharge recovery characteristics coupled with long life on float standby, are ideal for numerous applications in both cyclic and standby modes.  
Charging For Float Standby Applications  
Charged at 2.275 volts per cell continuous. The battery will seek its own current level and float fully charged. However, users should be aware that when charging from fully discharged, the battery can draw an initial charge current of approximately 2cA. Care should therefore be taken to ensure that this initial charge current (if ungoverned) is within the output capability of the equipment. Final charge current at 2.275 volts per cell is typically between 0.0005cA to 0.004cA.
Charging For Cyclic Applications  
See cyclic recharge regime graph.
NPH
High performance batteries specially designed for applications requiring high rate discharge, supplying up to 50% more power (Watts) for short durations when compared to conventional NP models.           5. Application1. E-bike  1.E-bike   2. Battery-powered wheelchairs   3. Golf trolleys   4. Ride-on toys   5. Electric scooters   6. Portable television and video equipment   7. Lifting equipment    8. Semi-traction lawn mowers     6. Factory view & Certificates    4.CONTACT US    
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628