50hz / 60hz Cummins Diesel Generator Stamford Alternator 20kw 25kva
50hz / 60hz Cummins Diesel Generator Stamford Alternator 20kw 25kva
50hz / 60hz Cummins Diesel Generator Stamford Alternator 20kw 25kva
50hz / 60hz Cummins Diesel Generator Stamford Alternator 20kw 25kva
50hz / 60hz Cummins Diesel Generator Stamford Alternator 20kw 25kva

1 / 3

50hz / 60hz Cummins Diesel Generator Stamford Alternator 20kw 25kva

Get Latest Price
Send Inquiry
Model No. :
Brand Name :

Product description

Product Name: 25kva Diesel Generator Rated Power: 25kva
Frequency: 50Hz Or 60Hz Rated RPM: 1500rpm Or 1800rpm
Rated Voltage: 120v/208v,220V/380V, 240V/415V Alternator: Stamford, Leroy Somer ,Marathon,Engga
Control Panel: Smartgen, Deepsea,ComAp

 

50hz / 60hz Cummins Diesel Generator Stamford Alternator 20kw 25kva

 

1.Output Power :25 kva
2.Cummins Diesel Engine:4BT3.9-G2
3.Stamford AC Alternator:PI144F

4.CE Approved

5.deepsea,Smartgen Control Panel

 

50Hz/60Hz Stamford Alternator Cummins Diesel Generator,25kva Diesel Generator Price

 

Type

            GNRC20

             Frequency(50/60HZ)

           20KW/25KVA

 

 

 

Standard configuration

 

 

Overall description:

  • Cummins Engine and Stamford Alternator
  • Water cooled radiator, the fans driven by belt, with        safety   shield.
  •  24 V Battery charging Alternator
  • Alternator:Single bearing Alternator,IP23 Grading   Protection, H Insulation degree
  • Shock absorber
  • Dry air filter,Fuel filter,Oil filter
  • Power output circuit breaker
  • Smartgen control panel(LCD display)
  • 12 V battery and battery connection cables
  • Exhaust pipe,Corrugated shock tube,flange,Muffler set
  • Maintenance manuals
  • Lubrication System

 

 

Sales commitment

 

   The products that we provide are all new, each unit all get through the strict production testing.

   12 months or 1000 hours(whichever occurs first) of Warranty Time for all our products. We take the full responsibility only in the fault that created by the quality, the wearing-parts, daily consumables and human error of operating & maintenance are not included in.

 

 

Criterion

  • GB/T19001-2008
  • SO9001:2008 Quality Control System

 

The main parameters of the generator set

 

 

Technical data

Genset Model

GNRC20

 Prime Power 

20kw

Rated Voltage

400/230V

Frequency

50/60Hz

Power Factor

0.8(lagging)

The regulating rate of steady voltage 

≤±0.5%

The regulating rate of instantaneous voltage 

≤-15%/ +20%

The time of steady voltage 

≤1.5sec

The waving rate of voltage 

≤1.0%

The regulating rate of steady frequency 

≤3%

The regulating rate of instantaneous frequency

≤±10%

The time of steady frequency

3sec

Dimension (L×W×H) (mm)

1650*720*1200

Genset weight (kg)

700

Diesel Engine

Brand

Cummins

Model

4B3.9-G2

Number of Cylinders

4

Rotating Speed

1500/18000RPM

Cycle

Four stroke

Type 

waste gas turbine boost,direct spurting type 

Bore×Stroke(mm)

102*120

Displacement(L)

3.9

Lubricating Capacity(L)

11

Speed Governor

Electrical 

Cooling System

Water-cooled

Speed Stability (%)

≤5%

Fuel Consumption at 100% Load

208g/kw.h

Starting Method

DC24V Electrical starting

Alternator

Brand

Stamford

Model

PI144F

Number of Phase

3

Connecting Type

Three Phase and Four Lines

Number of Bearing

1

Grading Protection

IP23

Altitude

≤1000m

Exciter Type

Brushless (AVR automatic voltage regulating)

Insulation Class

H degree

The components of the genset

(1) Cummins Diesel Engine;        (2) Stamford Alternator;     (3) Control Panel

Control Panel

The control panel is Quadruplication protection control panel, with the display of frequency table/water temperature/schedule/battery voltmeter. The genset with low oil pressure, high water temperature, over speed emergency, stop and other pre-protection.

 

 

Control Panel

 

1. Key switch (manual type) control panel 

Shock resist is fitted between control panel and generator set. Loose sheet is also fitted. The equipments 

of control panel are Meters with Voltmeter,Ammeter,Frequency list,Water thermometer,Oil pressure gauge,

Hour meter.

2. Control parts

Start/stop key switch, start button, emergency stop button, voltage regulation

resistance, speed regulation resistance. Voltage phase switch ,Electric current phase 

selecting switch.

3. Protection setting for engine

For emergency shut down, overfeed, high water temperature, low oil pressure. ATS switch is optional 

components when ome accidents appear, The digital Protector can shut down immediately, giving the 

battery voltage alarm and DC electrical source alarm. European extremity, steady wiring, and it can easily dismantle and install.

 The above generating set fitted with a base fuel tank for more than 8 hours using

 

 

Soundproof canopy:
1)With steel sheet
2)Stainless steel locks
3)Control panel viewing window for monitoring the status of the generator set
4)Good ventilation system and anti-heat radiation construction
5)Effective anti-vibration devices to ensure the generator set run steadily
6)Super silent materials inside to ensure the noise lower than 70 dB 7 meters away
7)Emergency stop button mounted outside
8)Side lockable door easy for maintenance and installation
9)Lube oil and cooling water drains piped to exterior of the canopy

 

 

 

Standard configuration supply scope:

 

(1)Diesel engine with all accessories,3 filter,electrical systems.
(2)Alternator.

 

(3)Steel structure.
(4)Fan and water cooling system.
(5)Flange connector.
(6)12v/24vstarting motor and charge engine.
(7)Air cleaner,fuel cleaner,oil cleaner.
(8)On-board control panel.
(9)MCCB air conservation switch.
(10)12v/24v starting accumulator and bettery line.
(11)Set shock absorber.

 

 

Cummins Engine

Original stamford alternator and certificate :

Cummins Open type Genset :

Silent Type Diesel Genset :

 

 

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628