300V FPLR Heat Resistant Cable with PVC Insulation Riser / Fire power limited cable

Quick Details

  • FPLR 22 AWG Fire alarm cable
  • Solid Copper conductor
  • unshielded types: 4C
  • shielded types: 4C
  • RISER PVC
  • 500ft , 1000ft
  • Fire power limited cable

Description

KINGTONE ELECTRONICS is the leading manufacturer of fire alarm system cables for the fire protection industry. Our innovative product line includes all power-limited cables for use in the NEC Article 760.
NATIONAL ELECTRIC CODE (NEC) ARTICLE 760: NEC Article 760 covers the installation of wiring and equipment of fire alarm systems,including all circutis controlled and powered by the fire alarm system.
These systems are defined in the NEC as " The portion of wiring system between the load side of the overcurrent devices or the power-limited supply and the connected equipment of all circuits powered
and controlled by the fire alarm system."
Type FPLR- FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run
in a shaft or from floor to floor.All FPLR cables are listed as having fire-resistantcharacteristics capable of preventing fire from traveling from floor to floor.Riser cables must pass both UL test 1424
and the Vertical riser test UL 1666.
KT1421 Fire Alarm Cables 22AWG FPLR-CL2R
PVC Insulation Riser
Application
Indoor for:
Audio Circuits
Control Circuits
Initiating Circuits
Notification Circuits
Properties
Temperature Rating: '-20 to 75℃
Operating Voltage: 300 Volts max.
Flame Rating: UL 1666(Riser),C(UL)FT4
Insulation & Jacket: PVC
Unshielded types
Conductors NOM.
THICKNESS
(MM)
Nominal
0.D.
Capacitance Impedance DC
Resistance
Number Solid Insulation Jacket Inch pf/ft Ohms Ohms/M'
4 22 AWG 0.006" 0.015" 0.118" 20 100 17
Shielded types
Conductors NOM.
THICKNESS
(MM)
Nominal
0.D.
Capacitance Impedance DC
Resistance
Number Solid Insulation Jacket Inch pf/ft Ohms Ohms/M'
4 22 AWG 0.006" 0.015" 0.126" 31 48 17.5
Drain Wire 24 AWG Solid Tinned-Copper
Shield 0.001" thick Aluminum/Mylar
Color
Number Description
4 Blk,Red,Ylw,Grn
6 Blk,Red,Ylw,Grn,Brn,Blu
8 Blk,Red,Ylw,Grn,Brn,Blu,Ppl,Pnk
10 Blk,Red,Ylw,Grn,Brn,Blu,Ppl,Pnk,Tan,Org
12 Blk,Red,Ylw,Grn,Brn,Blu,Ppl,Pnk,Tan,Org,BlkWht,RedWht
Order Informations:
Print

KINGTONE KT1421 ×C22 E×××××××(UL) FPLR OR

CL2R C(UL)US FT4 SUN RES(ROHS) ××××FT
DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9

Packing 1000FT/Pull Box, 1000FT/Spool, Pallet

Competitive Advantage:

1, From raw materials to final products, we perform intense quality checks to maintain our product quality:

A, Incoming material inspected by QC.

B, Manufacturing Process Control

C: Workers trained daily/weekly/monthly

D: Work instructions manual at each work station

E: 5S system implemented

F: Machine maintenance procedure

G: Quality Control and Final Inspection

The QC staff will check the material, process product

and final product according to the specification or test procedure.

2, Our R&D efforts center on reinforcing and developing element technologies

needed to support the future growth and success for customers and KINGTONE.

3, We know customers have urgent needs.

We are skilled at effective communication to interact with customers.

In order to provide prompt service, we can answer for you 7*24 hours.

4, We can Quickly and professionally answer for the inquire

5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us

6, Intime delivery

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628