1 / 6
Model No. : | YHY-12008000 |
---|---|
Brand Name : | YHYadapter |
Brand Name : | YHY |
Shenzhen, Guangdong, China
Product description
AC / DC 12V 2A Power Adapter - This AC / DC 12V 2A Power Adapter is a very safe adapter that has to overheat and short-circuit protected. The adapter comes in a portable physique and lightweight approach. You will get excellent quality with an incredible set of features, including protection against short circuits, over current protection, and overvoltage It is compact and easy to transport during travel. The input power is worldwide acceptable by having an input voltage of 110VAC to 240VAC.
1.12v 8a Switching Power Supply Electrical Specification
1.1. Input requirement
Item |
Minimum |
Nominal |
Maximum |
Unit |
Remark |
Rated Input Voltage |
|
100 / 240 |
|
Vac |
|
Input Voltage Range |
90 |
/ |
264 |
Vac |
|
Rated Frequency |
|
50 / 60 |
|
Hz |
|
Frequency Range |
47 |
/ |
63 |
Hz |
|
Input Current |
|
/ |
2.5 |
A |
at 100Vac/ 60Hz- at 240Vac/ 50Hz |
Input Inrush Current |
|
/ |
120 |
A |
Cool Start 120Vac |
Power Consumption |
|
/ |
0.21 |
W |
No Load |
1.2. Output requirement
1.2.1 Output voltage and current
The power supply output voltage must stay within the limits specified in table 2 when operating at steady state.
1.2.2 Ripple and Noise
Ripple and Noise are tested by dc loading side parallel with a 47uF/E-CAP and 0.1uF/ C-CAP and with 20MHz Band-Width, the result must be less than 120mV
1.2.3 Average Efficiency
The average efficiency is lager than 88.00% which is at 115Vac/60Hz and 230Vac/50Hz with 100%,75%,50%,25% rated load. This result comply with the DOE VI
1.2.4 Line regulation
The line regulation of rated output voltage is less than ±5% while measuring at rated load and +/-10% of input voltage changing.
1.2.5 Load regulation
The load regulation of rated output voltage is less than ±5% at measured output load from 10% to 100% rated load .
1.2.6 Turn on delay time
At nominal input AC voltage and full load, it must less than 4S
1.2.7 Rise time
The Supply shall have a start-up rise time of less than 30mS within regulation limits for all DC outputs.
1.2.8 Hold up time
At nominal input AC voltage and full load, it must larger than 10mS
1.2.9 Overshoot and undershoot
The output voltage over/undershoot upon the application or removal of the input voltage, under the input conditions specified in Section 2.1, shall be less than ±10% ,above the nominalvoltage. No voltage of opposite polarity shall be present on output during turn-on or turn-off.
1.2.10 Dynamic respose
The output voltage must between ±5% 20% to 80% load and back to 20% with a 0.15A/msec slew rate.