1 / 1
Model No. : | JKLYJ 1kV 1*120 |
---|---|
Brand Name : | Ruiyang Group |
Product description
JKLGYJ-10 10kV steel core aluminium XLPE insulation aerial cable | |||||||||
Nominal sectional aluminium/steel | Strucrure pair no./diameter | Out diameter reference | Inner shield thickness | Thickness | Out diameter | Conductor max resistance at 20℃ | Calculated breaking ≥ | Referenc eweight | |
Aluminium | Steel | ||||||||
(mm2) | (mm2) | (mm2) | (mm2) | (mm2) | (mm2) | (mm2) | (Ω/km) | (kg/km) | |
10/2 | 6/1.50 | 1/1.50 | 4.28 | 1 | 3.4 | 13.1 | 0.706 | 4120 | 159 |
16/3 | 6/1.85 | 1/1.85 | 5.27 | 1 | 3.4 | 14.1 | 1.779 | 6130 | 194 |
25/4 | 6/2.32 | 1/2.32 | 6.6 | 1 | 3.4 | 15.4 | 1.131 | 9290 | 270 |
35/6 | 6/2.72 | 1/2.72 | 7.75 | 1 | 3.4 | 16.6 | 0.823 | 12630 | 304 |
50/8 | 6/3.20 | 1/3.20 | 9.12 | 1 | 3.4 | 17.9 | 0.5496 | 16870 | 375 |
50/30 | 12/2.32 | 7/2.32 | 11.02 | 1 | 3.4 | 19.8 | 0.5692 | 42620 | 577 |
70/10 | 6/3.80 | 1/3.80 | 10.83 | 1 | 3.4 | 19.6 | 0.4217 | 23390 | 477 |
70/40 | 12/2.72 | 7/2.72 | 12.92 | 1 | 3.4 | 21.7 | 0.4141 | 58300 | 741 |
95/15 | 26/2.15 | 7/2.15 | 12.93 | 1 | 3.4 | 21.7 | 0.3058 | 35000 | 611 |
95/20 | 7/4.16 | 7/4.16 | 13.18 | 1 | 3.4 | 22 | 0.3019 | 37200 | 644 |
95/55 | 12/3.20 | 7/3.20 | 15.2 | 1 | 3.4 | 24 | 0.2992 | 78110 | 969 |
120/7 | 18/2.90 | 1/2.90 | 13.78 | 1 | 3.4 | 22.6 | 0.2422 | 27570 | 622 |
120/20 | 26/2.38 | 7/1.85 | 14.32 | 1 | 3.4 | 23.1 | 0.2496 | 41000 | 716 |
120/25 | 7/4.72 | 7/2.10 | 14.95 | 1 | 3.4 | 23.8 | 0.2345 | 47880 | 787 |
120/70 | 12/3.60 | 7/3.60 | 17.1 | 1 | 3.4 | 25.9 | 0.236 | 98370 | 1182 |
150/8 | 18/3.20 | 1/3.20 | 15.2 | 1 | 3.4 | 24 | 0.1989 | 32860 | 723 |
150/20 | 24/2.78 | 7/1.85 | 15.84 | 1 | 3.4 | 24.6 | 0.198 | 46630 | 817 |
150/25 | 26/2.70 | 7/2.10 | 16.25 | 1 | 3.4 | 25.1 | 0.1939 | 54110 | 878 |
150/35 | 30/.2.5 | 7/2.50 | 16.63 | 1 | 3.4 | 25.4 | 0.1962 | 65020 | 962 |
185/10 | 18/3.60 | 1/3.60 | 17.1 | 1 | 3.4 | 25.9 | 0.1572 | 40880 | 870 |
185/25 | 24/3.15 | 7/2.10 | 17.96 | 1 | 3.4 | 26.8 | 0.1542 | 59420 | 1006 |
185/30 | 26/2.98 | 7/2.30 | 17.94 | 1 | 3.4 | 26.7 | 0.1592 | 64320 | 1029 |
185/45 | 30/2.80 | 7/2.80 | 18.62 | 1 | 3.4 | 27.4 | 0.1564 | 80190 | 1154 |
210/10 | 18/3.80 | 1/3.80 | 18.05 | 1 | 3.4 | 26.9 | 0.1411 | 45140 | 952 |
210/25 | 24/3.33 | 7/2.22 | 18.98 | 1 | 3.4 | 27.8 | 0.138 | 65990 | 1101 |
210/35 | 26/3.22 | 7/2.50 | 19.36 | 1 | 3.4 | 28.2 | 0.1363 | 74250 | 1172 |
210/50 | 30/2.98 | 7/2.98 | 19.82 | 1 | 3.4 | 28.6 | 0.1381 | 90830 | 1283 |
240/30 | 24/3.60 | 7/2.40 | 20.52 | 1 | 3.4 | 29.3 | 0.1181 | 75620 | 1253 |
240/40 | 26/3.42 | 7/2.66 | 20.58 | 1 | 3.4 | 29.4 | 0.1209 | 83370 | 1298 |
240/55 | 30/3.20 | 7/3.20 | 21.28 | 1 | 3.4 | 30.1 | 0.1198 | 102100 | 1451 |
300/15 | 40/3.00 | 7/1.67 | 21.86 | 1 | 3.4 | 30.7 | 0.0972 | 68060 | 1292 |
300/20 | 45/2.93 | 7/1.95 | 23.21 | 1 | 3.4 | 32 | 0.0952 | 75680 | 1369 |
300/25 | 48/2.85 | 7/7.22 | 22.57 | 1 | 3.4 | 31.4 | 0.0943 | 83410 | 1419 |
300/40 | 24/.3.99 | 7/2.66 | 22.74 | 1 | 3.4 | 31.5 | 0.0961 | 92220 | 1493 |
300/50 | 26/3.83 | 7/2.98 | 23.05 | 1 | 3.4 | 31.9 | 0.0964 | 103400 | 1580 |
300/70 | 30/3.60 | 7/3.60 | 23.94 | 1 | 3.4 | 32.7 | 0.0946 | 128000 | 1778 |
400/20 | 42/3.51 | 7/1.95 | 25.56 | 1 | 3.4 | 34.4 | 0.071 | 88850 | 1687 |
400/25 | 45/3.33 | 7/2.22 | 25.31 | 1 | 3.4 | 34.1 | 0.0737 | 95940 | 1690 |
400/35 | 48/3.22 | 7/2.50 | 25.48 | 1 | 3.4 | 34.3 | 0.0739 | 103900 | 1748 |
400/50 | 54/3.07 | 7/3.07 | 26.25 | 1 | 3.4 | 35.1 | 0.0723 | 123400 | 1922 |
400/65 | 26/4.22 | 7/3.44 | 26.6 | 1 | 3.4 | 35.4 | 0.0724 | 135200 | 2024 |
400/95 | 30/4.16 | 19/2.50 | 27.68 | 1 | 3.4 | 36.5 | 0.0709 | 171300 | 2298 |
500/35 | 45/3.75 | 7/2.50 | 28.5 | 1 | 3.4 | 37.3 | 0.0581 | 119500 | 2080 |
500/45 | 48/3.60 | 7/2.80 | 28.5 | 1 | 3.4 | 37.3 | 0.0591 | 128100 | 2126 |
Model | Name | NO. of cores | Nominal section(mm) | `Usage |
JKLGY | 10kV steel core aluminium XLPE insulation aerial cable | 2-65 | 10-500 | It is applicable to fix and lay down 10KV overhead power line. To extend cables, it shall be taken into consideration to keep a certain distane between cable and tree.And it is permitted to have frequent contacts between cable and tree while the cable is in operation. |
JKYJ,JKTRYJ | 10kV Copper XLPE PE insulation aerial cable | 1 | 25-240 | To extend cables ,it shall be taken into consideration to keep a certain distance between cable and tree, it is permitted to have frequent contacts between cable and tree when cable is in operation.Soft copper-core is used to lead wire out for transform when over-head,fix and lay down the cable. |
3 | 25-120 |
Send your inquiry to this supplier