100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator
100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator
100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator
100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator
100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator

1 / 3

100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator

Get Latest Price
Send Inquiry
Model No. : SXCF
Brand Name :

Product description

  • Model NO.: SXCF
  • Display: LCD
  • Power Source: 380V/220V110V at Cutomized
  • Rated Energy: 10kj or at Customized
  • Each Stage: 100kv 0.25UF or at Customized
  • Transport Package: Plywood Cases
  • HS Code: 9030339000
  • Accuracy Grade: 0.5
  • Control: Computer Control
  • Nominal Voltage: 200kv or at Customized
  • Impulse Capacitance: 0.5UF or at Customized
  • Trademark: Sansion Power
  • Origin: Wuhan, China
System instruction Main Parameters for System
  • Nominal voltage: ±200kV          
  • Rated stage voltage: ±100kV
  • Rated energy: 10kJ
  • Impulse capacitance: 0.5µF
  • Number of stages: 2
  • Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)
  • Impulse voltage waveform: generated when load capacitance is 300-3000pF.
T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of  peak voltage deviation≤3%;
Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage  waveform parameters and error are accorded with national requirements of IEC standard.
  • Voltage utilization factor: Standard lightning impulse voltage waveform ≥90% when load capacitance is below 1000pF, standard operation impulse voltage waveform≥80% when load capacitance is below 2000pF. Standard operation impulse voltage waveform ≥70%.
  • Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.
  • Out-of-control rate of synchronous discharge: <5%
  • Min. output voltage: ≥±20% of rated voltage.
  • Instability of discharge voltage: <±1.0%
  • Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.

100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator

100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator
100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator
100 Kv / 5 Kj Impulse Voltage Test System, High Voltage Impulse Generator
More details please contact Sansion Power by email for further information.