0.3mm cable wire thermocouple type k
0.3mm cable wire thermocouple type k
0.3mm cable wire thermocouple type k
0.3mm cable wire thermocouple type k
0.3mm cable wire thermocouple type k

1 / 3

0.3mm cable wire thermocouple type k

Get Latest Price
Send Inquiry
Model No. : k type thermocouple compensation wire
Brand Name : SZNK
9yrs

Suzhou city, Jiangsu, China

Visit The Store

Product description

  PRODUCT DETAILS thermo couple wire  
1. Stable EMF value  2. Precious test result 3. IEC584-1 IEC584-2 standard  4. EN 10204-3.1 certificate                                               thermocouple wire, thermo couple wire     
                                     Thermocouple wire (Type K, N, E, J, T, S, B, R)    Thermocouples are widely used within industry as a method of measuring temperature and the Thermocouple Wire is the means to transfer the measurement from the source to the recording instruments. The principle of joining two different metals to create a voltage is the basis for all thermocouples and we manufacture the major Types and Grades to meet the wide range of applications from small measuring instruments to heavy chemical and power generation plants. standards  We manufactures Type N, K, E, J and T in Thermocouple and Extension grades to Class 1 and 2 calibrations. Wires are manufactured to the appropriate part of BS EN 60584 - IEC 584. and to ANSI MC96. 1:1982. We can also comply with other standards and full calibration and EMF testing is performed at SGS laboratory with Certificates of Conformity supplied upon request.     Specifications  

ISA

Material
(+ & -)

Temperature

Range°C 
(°F)

Sensitivity@ 
25°C (77°F)
µV/°C
(µV/°F)

Error*

App.**

E

Chromel & Constantan
(Ni-Cr & Cu-Ni)

-270~1000
(-450~1800)

60.9
(38.3)

LT:±1.67°C(±3°F)
HT:±0.5%

I,O

J

Iron & Constantan
(Fe & Cu-Ni)

-210~1200
(-350~2200)

51.7
(28.7)

LT:±2.2~1.1°C(±4~2°F)
HT:±0.375~0.75%

I,O,R,V

K

Chromel & Alumel
(Ni-Cr & Ni-Al)

-270~1350
(-450~2500)

40.6
(22.6)

LT:±2.2~1.1°C(±4~2°F)
HT:±0.375~0.75%

I,O

T

Copper & Constantan
(Cu & Cu-Ni)

-270~400
(-450~750)

40.6
(22.6)

LT:±1~2%
HT:±1.5% or ±0.42°C(±0.75°F)

I,O,R,V

R

Platinum & 87% Platinum/ 

13% Rhodium
(Pt & Pt-Rh)

-50~1750
(-60~3200)

6
(3.3)

LT:±2.8°C(±5°F)
HT:±0.5%

I,O

S

Platinum & 90% Platinum/ 

10% Rhodium
(Pt & Pt-Rh)

-50~1750
(-60~3200)

6
(3.3)

LT:±2.8°C(±5°F)
HT:±0.5%

I,O

B

70% Platinum/ 30% Rhodium 

94% Platinum/ 6% Rhodium

(Pt-Rh & Pt-Rh)

-50~1750
(-60~3200)

6
(3.3)

LT:±2.8°C(±5°F)
HT:±0.5%

I,O

 

*: 

LT = Low temperature range, HT = High temperature range 

**: 

I = Inert media, O = Oxidizing media, R = Reducing media, V = Vacuum 

  

Constantan, Alumel, and Chromel are trade names of their respective owners. 


  PRODUCT IMAGE           Thermocouple wire, thermo couple wire      Type K (Chromel / Alumel)
Type K is the ‘general purpose’ thermocouple. It is low cost and, owing to its popularity, it is available in a wide varietyof probes. Thermocouples are available in the -200 °C to +1200 °C range. Sensitivity is approx 41 µV/°C.  Use type K unless you have a good reason not to.   Type E (Chromel / Constantan)
Type E has a high output (68 µV/°C)  which  makes it well suited to low temperature (cryogenic) use.  Another property is that it is non–magnetic.   Type J (Iron / Constantan)
Limited range (-40 to +750 °C) makes type J less popular than type K. The main application is with old equipment that can not accept ‘modern’ thermocouples. J types should not be used above 760 °C as an abrupt magnetic transformation will cause permanent decalibration.   Type N (Nicrosil / Nisil)
High stability and resistance to high temperature oxidation makes type N suitable for high temperature measurements without the cost of platinum (B,R,S) types. Designed to be an ‘improved’ type K, it is becoming more popular.   Thermocouple wire, thermo couple wire 
   Thermocouple types B, R and S are all 'noble' metal thermocouples and exhibit similar characteristics. They are the most stable of all thermocouples, but due to their low sensitivity (approx 10 µV/°C)  they are usually only used for high temperature measurement (>300 °C).   Type B (Platinum / Rhodium)
Suited for high temperature measurements up to 1800 °C. Unusually type B thermocouples (due to the shape of theirtemperature / voltage curve) give the same output at 0 °C and 42 °C. This makes them useless below 50 °C.   Type R (Platinum / Rhodium)
Suited for high temperature measurements up to 1600 °C. Low sensitivity (10 µV/°C) and  high cost makes them unsuitable for general purpose use.   Type S (Platinum / Rhodium)
Suited for high temperature measurements up to 1600 °C. Low sensitivity (10 µV/°C) and high cost makes them unsuitable for general purpose use. Due to its high stability type S is used as the standard of calibration for the melting point of gold (1064.43°C).   When selecting thermocouple types, ensure that your measuring equipment does not limit the range of temperaturesthat can be measured. Listed below is the range of temperatures that the 8 channel Pico TC-08 can  measure. Note that thermocouples wit    PRODUCT PROCESS   TEST EQUIPMENT     PRODUCT PACKAGE     CERTIFICATES   Company Information     WHY CHOOSE SZNK HIGH QUALITY RESISTANCE HEATING ALLOYS?   1.Competitive price,   We are manufacture, so you get directly from factory that is actively controlling for mutual benefit.   2.Quality Control System   With experienced engineers and QA workers, each manufacturing process is checked and audited strictly. Incoming quality control conducts inspections and handle quality issues before the assembly process starts. Our In-Process Quality Control process governs our quality systems during the assembly process in order to detect and handle any problems that may arise during assembly. Outgoing quality assurance is the last process before products ship to customers, and hence is very important in ensuring our shipment is defect-free. Numerous redundancies with IQC and IPQC exist here to ensure the validity of previous processes.   3.OEM services   The factory can produce the product according to the client's engineering drawings. Client's mark can be labeled on packaging for OEM products.   4.Short lead time and prompt shipment    How to contact us?   Send your inquiry details in the below for free sample, click "send" now.
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628